MUMBAI

TEST CERTIFICATE

DIGITAL COATING THICKNESS GAUGE

This Test Certificate warrantees that the product has been 

inspected  and  tested  in  accordance  with  the  published 

specifications.

The  instrument  has  been  calibrated  by  using  equipment 

which has already been calibrated to standards traceable 

to national standards.

MODEL NO. ________________

KM 117A

SERIAL NO. ___________

DATE: ___________

ISO 9001

REGISTERED

QC

PASS

KUSAM-MECO

20

WARRANTY

Each “KUSAM-MECO” product is warranted to be free from defects in 
material and workmanship under normal use & service.  The warranty 
period is one year (12 months) and begins from the date of despatch of 
goods.   In case any defect occurs in functioning of the instrument, 
under proper use, within the warranty period, the same will be rectified 
by us free of charges, provided the to and fro freight charges are borne 
by you.
This warranty extends only to the original buyer or end-user customer 
of a “KUSAM-MECO” authorized dealer.
This warranty does not apply for damaged Ic’s, fuses, burnt PCB's, 
disposable batteries, carrying case, test leads, or to any product which 
in “KUSAM-MECO’s” opinion, has been misused, altered, neglected, 
contaminated  or  damaged  by  accident  or  abnormal  conditions  of 
operation or handling.
“KUSAM-MECO” authorized dealer shall extend this warranty on new 
and unused products to end-user customers only but have no authority 
to extend a greater or different warranty on behalf of “KUSAM-MECO”.
“KUSAM-MECO’s”  warranty  obligation  is  limited,  at  option,  free  of 
charge repair, or replacement of a defective product which is returned 
to a “KUSAM-MECO” authorized service center within the warranty 
period.
THIS WARRANTY IS BUYER’S SOLE AND EXCLUSIVE REMEDY 
AND  IS  IN  LIEU  OF  ALL  OTHER  WARRANTIES,  EXPRESS  OR 
IMPLIED,  INCLUDING  BUT  NOT  LIMITED  TO  ANY  IMPLIED 
WARRANTY  OF  MERCHANTABILITY  OR  FITNESS  FOR  A 
PARTICULAR PURPOSE.  “KUSAM-MECO” SHALL NOT BE LIABLE 
F O R   A N Y   S P E C I A L ,   I N D I R E C T,   I N C I D E N TA L   O R  
CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF 
DATA, ARISING FROM ANY CAUSE WHATSOEVER.
All transaction are subject to Mumbai Jurisdiction.

Содержание KM 117A

Страница 1: ...Distance Meter Digital Lux Meter Network Cable Tester Power Factor Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency C...

Страница 2: ...GAUGE MODEL KM 117A TABLE OF CONTENTS TITLE PAGE NO I II Features VI Introduction III Safety Information V Product Use Maintenance VIII Test Certificate IX Warranty IV Specifications Measurements VII...

Страница 3: ...in an environment where it will be directly illuminated by sunshine or where it condensation If you do it may be deformed its insulation may be damaged or it may no longer function according to speci...

Страница 4: ...r away from the interfered source at least 30cm B Electromagnetic Field Strength unit mini Gauss Electromagnetic Source Cellular Phone Charger Notebook Power Supply LCD Display Fan Reading Lamp Any pr...

Страница 5: ...ery Accessories User Manual Battery carrying case 2 Electrical Specifications Detectable Substrate Material Ferrous metal iron steel Thickness Range 0 80 0mils 0 2000m m Display Resolution 0 1mils 1m...

Страница 6: ...ress the button for 2 seconds to clear Calibrating Point BASE 2S ZERO During measure mode DEL ESC The three buttons are disabled During setting mode The two buttons are disabled 2S BASE 2S ZERO 08 4 T...

Страница 7: ...kness is out of range the meter shows CAUTION Keep the sensing tip of the meter away from any substrate or any magnetic field 4 When the alarm is activated measured exceed Hi Limits or Lo Limits LCD d...

Страница 8: ...CAL h Into Hi value adjustments of the two point calibration press or button to adjust reading when it display the desired value press button to confirm MENU 12 Press the tip of the Gauge to contact c...

Страница 9: ...lete or yes press button to return to browse previous records MENU yes press button to delete record and return to the measuring mode MENU Fe m m MEM ec o MAX 14 al Alarm Setting Fe m m al In this mod...

Страница 10: ...et the desired value press button to confirm the Hi Limits alarm and return to measuring mode MENU Alarm setting Maximum is 2000m m 78 7 mils Minimum is 0 m 0 mils m 16 u Unit Selecting In this mode p...

Страница 11: ...range the meter shows 18 VII MAINTENANCE Installing and Replacing Battery 1 Power is supplied by 2pcs 1 5V AAA size 2 The appears in the display when battery replacement is needed 3 Remove the batter...

Страница 12: ...authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altere...

Отзывы: