background image

®

®

AN ISO 9001:2015 COMPANY

MODEL - KM 035

OPERATION MANUAL

G 17, Bharat Industrial Estate, T. J. Road, 

Sewree (W), Mumbai - 400 015. INDIA. 

Sales Direct :

 (022) 24156638

Tel. :

 (022) 24124540, 24181649. 

Fax :

 (022) 24149659

Email :

 [email protected] 

Website : 

www.kusamelectrical.com 

              www.kusam-meco.co.in

®

LIST OF PRODUCTS

 Digital Multimeter                    

 Digital AC & AC/DC Clampmeter

 AC Clamp Adaptor                  

 AC/DC Current Adaptor

 Thermo Anemometer               

 Thermo Hygrometer

 Distance Meter                        

 Digital Lux Meter

 Network Cable Tester              

 Power Factor Regulator

 Earth Resistance Tester           

 Digital Panel Meters

 DC Power Supplies                 

 High Voltage Detector

 Calibrators                               

 Gas Analysers

 Frequency Counter                  

 Function Generator

 Phasing Sticks                         

 Battery Tester

 Waterproof Pen Testers           

 Solar Power Meter

 EMF Detector

 Wood, Paper & Grain Moisture Meter

 Transistorised Electronic Analog & Digital Insulation   

    Resistance Testers(upto 10 KV)

 Digital Sound Level Meter & Sound Level Calibrator

 Digital contact & Non-contact Type Tachometer

 Digital Non-contact (infrared) Thermometer

 Maximum Demand Controller/Digital Power Meter

 Digital Hand Held Temperature Indicators

AC/DC TRUE RMS 

DIGITAL CLAMPMETER WITH 

EF-DETECTION, AMPTIP FUNCTION 

FOR LOW CURRENT 

MEASUREMENT 

Содержание KM 035

Страница 1: ...or Regulator Earth Resistance Tester Digital Panel Meters DC Power Supplies High Voltage Detector Calibrators Gas Analysers Frequency Counter Function Generator Phasing Sticks Battery Tester Waterproo...

Страница 2: ...nd CAT IV 300V AC DC TERMS IN THIS MANUAL WARNING Identifies conditions and actions that could result in serious injury or even death to the user CAUTION Identifies conditions and actions that could c...

Страница 3: ...lled before the main fuse or circuit breaker in the building installation 03 II CENELEC Directives The instruments conform to CENELEC Low voltage directive 2014 35 EU Electromagnetic compatibility dir...

Страница 4: ...s APO Consumption typical 5 A Dimension 188 L x 66 W x 32 H mm Weight approx 202 gms 05 SAFETY Safety Certified per IEC UL CSA_C22 2_ EN standards 61010 1 Ed 3 0 61010 2 032 Ed 3 0 61010 2 033 Ed 1 0...

Страница 5: ...readings if any Range 1 2 Accuracy Resolution 2 0 rdg 5dgts 0 1 A 600 0 A 07 600 0 V 1 0 rdg 5dgts DC VOLTAGE Accuracy Resolution Range 0 1 V Input Impedance 10M 100pF nominal AC VOLTAGE with Digital...

Страница 6: ...V 500V 160V 80V 20V 140V 320V 80V 560V 09 VI PRODUCT DESCRIPTION This manual uses only representative model s for illustrations Please refer specification details for function availability to this mod...

Страница 7: ...of only one single pole of a circuit for load current measurements Make sure the jaws are completely closed or else it will introduce measure ment errors Enclosing conductors of more than one pole of...

Страница 8: ...AT IV A Hz COM 300V CAT IV 28 0 600V CAT III SELECT V V CREST REC EF A A 1 Press SELECT button momentarily to select DCA function 13 OFF MAX 600A 600V CAT III 300V CAT IV A Hz COM 300V CAT IV 32 600V...

Страница 9: ...ing further drops below 0 100V the meter gives a continuous beep tone together with flashing display back light to indicate a shorted diode or a complete wire it is similar to TM TM that of BeepLit Co...

Страница 10: ...th connections Probe Contact EF Detection For more precise indication of live wires such as distinguishing between Live and Ground connections use one single probe to test via terminal COM for direct...

Страница 11: ...is mode Auto Power Off is disabled automatically in this mode 19 C 5ms CREST MODE Press CREST button for one second or more to activate CREST mode instantaneous PEAK HOLD to capture current or voltage...

Страница 12: ...E To avoid electrical shock disconnect the meter from any circuit remove the test leads from the input jacks and turn OFF the meter before opening the case Do not operate with open case WARNING If the...

Страница 13: ...authorized dealer This warranty does not apply for damaged Ic s fuses burnt PCB s disposable batteries carrying case test leads or to any product which in KUSAM MECO s opinion has been misused altered...

Отзывы: