![Kusam-meco 276HD Скачать руководство пользователя страница 4](http://html.mh-extra.com/html/kusam-meco/276hd/276hd_instruction-manual_2011857004.webp)
01
®
®
02
FEATURES :
1. Telescopic, compact, light-weight
The length is elastic from 354mm to 1005mm, The equipment is
light-weight (180g), easy to handle, and handy to carry.
2. High-voltage detectable
The equipment, whether in stretched state is available for
voltage detection in high-tension circuits (3.3kV, 6.6kV and 24kV)
whether the wires involved are naked or insulated.
3. Low-voltage detectable
The equipment can be used for voltage detection in low-tension
circuits (80V ~ 600V) by holding the nameplate portion of the
detecting head. Before-use check can easily be done by
plugging in an AC 100V plug socket, without using a tester.
4. Easy to recognize indication
Intermittent lighting in red of a high intensity light-emitting diode
and intermittent audible sound of an electronic buzzer are readily
recognizable at a full daylight, noisy location.
5. Waterproof
The detecting head, being tightly enclosed, is free from any
trouble due to dust, dirt, water or the like.
RATINGS AND SPECIFICATIONS :
Working voltage range :
H.V. : 3kV~24kV AC hold grip portion to detect.
L.V. : 80V~600V AC hold nameplate portion to detect.
Frequency :
50Hz / 60Hz
Operation start Voltage (voltage to ground) :
When detecting while holding grip portion, naked wire
3mm
contacted 250V ± 50V AC O.C. wire,
Æ
5mm, contacted 1000V AC
± 200V AC.
Æ
When detecting while holding nameplate portion, contacted 80V
AC or below.
Operation start distance :
Distance at which operation starts when front metal is brought near
5mm O.C. wire with grip portion meld by hand.
Where 24kV / 3mm (voltage to ground) abt 20cm.
Where 6.6kV / 3mm (voltage to ground) abt 3cm.
When detecting while holding nameplate portion, contacted 80V
AC or below.
Operation start distance :
Distance at which operation starts when front metal is brought near
5mm O.C. wire with grip portion meld by hand.
Where 24kV /
Æ
3mm (voltage to ground) abt 20cm.
Where 6.6kV /
Æ
3mm (voltage to ground) abt 3cm.
Where 3.3kV /
Æ
3mm (voltage to ground) abt 1cm.
Dielectric Strength :
Put high voltage on the parts listed below.
(a) Between Sensing tip ~ Grip portion : 50kV AC, 1 min (The
detector has to be stretched)
(b) Between Sensing tip ~ Nameplate portion : 4kV AC, 1min.