26
3BA00133 • 2013-06-25 • Rev. 5
ersa IRHP 200
Functional discription/Error diagnosis
6.5
O
ffset table
The following table shows the temperature difference between the controller display and
the actual surface temperature of the glass plate.
Note:
The table is only valid in connection with the glass plate and not with the
power grid.
Temperature
heater
(RA 4500 D)
Typ.
plate temperature
(IRHP 200)
Note
Temperature
heater
(RA 4500 D)
Typ.
plate temperature
(IRHP 200)
100 °C
65 °C
212 °F
149 °F
150 °C
90 °C
Recommended
preheating range
302 °F
194 °F
200 °C
120 °C
392 °F
248 °F
250 °C
150 °C
482 °F
302 °F
300 °C
180 °C
572 °F
356 °F
350 °C
210 °C
662 °F
410 °F
400 °C
240 °C
752 °F
464 °F
450 °C
270 °C
842 °F
518 °F
500 °C
295 °C
Short-time
932 °F
563 °F
550 °C
320 °C
1022 °F
608 °F
600 °C
345 °C
1112 °F
653 °F
7.
Error diagnosis
7.1
General errors
If the control station does not operate as
expected, check the following items:
•
Mains voltage present? (Correctly connect the mains lead to the
device and socket.)
• Is the fuse defective? The control
station does not have its own load
protection, so that the voltage supply is exclusively protected by the
series fuse of the mains connection.
•
Is the hot plate correctly connected to the supply unit?
If the soldering tip does not become hot after the above items have been checked, the
cause may lie with the hot plate itself or with the temperature sensor. You can check the
continuity in the temperature sensor with an ohmmeter.
Содержание IRHP 200
Страница 11: ...11 3BA00133 2013 06 25 Rev 5 ersa IRHP 200 Funktionsbeschreibung 6 4 Kennlinien...
Страница 16: ...16 3BA00133 2013 06 25 Rev 5 ersa IRHP 200 Notizen...
Страница 17: ...Ersa IRHP 200 Rework heating plate Operation Manual...
Страница 25: ...25 3BA00133 2013 06 25 Rev 5 ersa IRHP 200 Functional discription 6 4 Characteristic...
Страница 30: ...30 3BA00133 2013 06 25 Rev 5 ersa IRHP 200 Notes...
Страница 31: ...31 3BA00133 2013 06 25 Rev 5 ersa IRHP 200 Notes...