41
3BA00226 • 2016-11-16 • Rev. 2
Ersa HR 200
■
Set the output level of the top heater using control knob
⑨
. If available and desired,
adjust the output level for the bottom heater using control knob
⑪
.
CAUTION! Burn hazard!
All the heated components of the device and the surrounding housing
parts as well as the PCB holder, the PCB and the components become hot.
CAUTION! Risk of poisoning by inhalation!
When soldering, harmful gas emissions are generated. Provide adequate
ventilation or extraction. Please observe the safety data sheets of the
solder pastes and fluxes used.
■
When using the optional bottom heater for high-mass PCBs, wait a certain time for
the PCB to be preheated before pressing the foot switch. Optionally, the tempera
-
ture sensor AccuTC and the temperature measurement device 0DTM103 (see list of
accessories) can be used.
■
By pressing the foot switch, the heating process of the top heater and – if enabled –
of the optional bottom one is started.
■
When the solder is molten, release the foot switch. If necessary, switch off the bot
-
tom heater using control knob
⑪
or the mains switch of the heating plate and let the
PCB cool down.
We recommend using fume extraction system (e.g. Ersa EASY ARM 1).
6.3.4
Switch-off
■
Switch off the HR 200 using the
③
mains switch.
CAUTION! Burn hazard
!
After switching off, wait until the device and the PCB have cooled down
and reached non-hazardous temperatures!
Function description