Monitor mode

Pressing the 

F4 = MON

 key activates the monitor mode, in which a data-safe, 

high-impedance listening („monitoring“) of the line is possible.
In monitor mode, the second line of the display shows from left to right:
  M 

 For 

MON

itor mude

  T oder P   Set dial, tone or pulse

  - oder I   Low Voltage Lockout off or on

  - oder 0   One-position counter for charge pulse

  Batterie   Display of battery capacity

  +005 

 Display of polarity (- or +) and three-digit display of line voltage, 

max. 199 V

If connected correctly to the line, the A-wire is 

minus

 and the B-wire is 

plus

Listening into the line can be done either by using the handset or the loudspe-

aker. This makes it easy to limit disturbances such as earth voltage, noise, 

etc. or to determine that the line is occupied.
The open listening mode is activated with the 

SPKR On / Off

 on the display 

side. The volume can be adjusted in 6 steps with the 

Vol +

 and 

Vol -

 keys. 

These keys are greatly delayed to prevent incorrect operation.
In monitor mode the 

DIGIT-GRABBER

 function is active. The 

DIGIT-GRAB-

BER

 function decodes the number dialed by the terminal (e.g. telephone, 

fax, modem, alarm dialer) and displays it. The maximum length displayed is 

48 characters.

CID RCL (Caller ID Recall)

The 

CID RCL

 key stores all transmitted information of the last three calls (e.g. 

phone number, name, date and time), if offered by the network operator. In 

talk mode, the stored information can be recalled by pressing the key repea-

tedly and selected with 

SEL

.

Содержание TP09D

Страница 1: ...cts only with written permission of Kurth Electronic GmbH All trademarks and logos mentioned herein belong to their registered owners TP09D Analogue Test Telephone User guide Kurth Electronic GmbH Mue...

Страница 2: ...and function keys Removable hook Control buttons Up Down Control buttons Right Left On Off Alphanumeric keypad Battery compartment lid Speaker mode Volume Volume Select button SEL LCD monitor with ba...

Страница 3: ...ing for monitor and tele phony and calling Main functions RING TP09D switched off Default setting is on hook Waiting for incoming call with or without CLIP information TALK TP09D switched on Pressing...

Страница 4: ...itted information is displayed and stored un der CID RCL The last three calls are stored in the CID RCL memory If no CLIP is trans mitted the information NO CLIP DETECTED If the information is transmi...

Страница 5: ...position counter for charge pulse 47 mA Current line current depen ding on the terminal device at LLC Battery Display of battery capacity 5 V Display of polarity or and three digit display of line vo...

Страница 6: ...imit errors in telephone systems as easily as possible the flash time the three most important times are adjustable via the Flash times option in the menu is set to a direct key The pause can be inser...

Страница 7: ...disturbances during normal conversations or calls ON OFF Advanced funtions For further functions the TP09D is switched on using the red ON OFF key keep the key pressed for more than one second The fol...

Страница 8: ...2 Tone 2 Pulse mode 1 10 pps 33 66 2 40 pps 40 60 3 CID mode 1 V23 DT AS 4 SMS options 1 SMS center 1 Number 2 Display SMS text 1 On 2 Off 3 Exit 5 Meter pulse 1 12 kHz 2 16 kHz 6 Line test mode 1 Off...

Страница 9: ...andset or the loudspe aker This makes it easy to limit disturbances such as earth voltage noise etc or to determine that the line is occupied The open listening mode is activated with the SPKR On Off...

Страница 10: ...tem NOSMS must be selected in the menu If the settings are correct the display shows the sequence of the SMS transmission and if the transmission was successful SMS OK as the result All parameters as...

Страница 11: ...ge is shown in the display The MWI status ON or OFF is also displayed CIDCW Option depending on network operator If another call arrives during a call Caller ID Call Waiting its call number is shown i...

Страница 12: ...sec and Flash both also multiple times can be inserted and saved Press F2 STO to save Dialling from the speed dial memory The line is assigned the TALK key LNR Re dialling the last three outgoing numb...

Страница 13: ...s displayed without sign in monitor and talk mode In this case the negative pole is on the A wire and the positive pole on the B wire The black test cord is intended for connection to earth but is as...

Страница 14: ...captive screws Make sure the polarity is correct when inserting the battery Use only good quality batteries The TP09D is waterproof Only the battery com partment and the test cord connection area are...

Страница 15: ...10 indirect memory locations with 24 digits each Monitor Impedanz 120 kOhm bei 100 kHz 500 kOhm bei 4 kHz General device data Power supply 9 V Alkaline Battery Display Graphical display Housing Stabl...

Страница 16: ...t was not intended can lead to incorrect measure ments and may damage the device The relevant safety regulations in VDE 0100 0800 and 0805 must be adhered to The usage of connections other than those...

Отзывы: