Operating Manual
KE7200 / KE7100
19
KURTH ELECTRONIC FERNMELDETECHNIK
www.kurthelectronic.de [email protected]
Sixteen common versions are predefined. The abbreviations UTP, STP,
and CR are described on
page 10 under Wiring
. The list appears after the
menu item "
Wiring definition
" is selected. The first item is "NO TEST". Do
not change this one.
After selecting a wiring version to be changed or the last "
NOT USED
"
item, the "
Name:
" menu appears
You can enter a unique wiring name such as "568C." Fifteen characters
are available. At the flashing cursor position, press the ▲ and ▼ buttons
to scroll through the alphabet and the numbers 0-9 including a space.
Select the character or number at the cursor position by pressing SEL.
Once the name is entered, confirm it by pressing SEL.
The "
Connections
" menu appears. The assignment
PIN to PIN
and
wire pair
can be made that corresponds to the wiring
version. This assignment is needed for identifying split pairs and
good/bad information after the test. The scroll bar is at
Pin
to
Pin
line pair
1
NC
none
.
Select it by pressing SEL. You are then in the menu
"
Connection to pin 1
"
An option appears where you can select all 8 pins that can be assigned
to pin 1. Press the ▲ and ▼ buttons to select the right pin and press
SEL.
You then go the menu
"
Pair
"
You can now assign the selected pins to a pair by pressing SEL.
You then go to the menu
"
Connections
"
The assignment of the first pin is displayed. Press the ▼ button to move
the scrollbar to the next item and continue as before with the assignment.
The assignments cannot be deleted. If you make incorrect assignments
while practicing, you can correct them. As an alternative, you can select
the item "Device settings/reset to defaults." This resets all definitions that
you have created.