Instructions for use and installation instructions
24
Placing and Installation
Choosing the Right Place
Place the appliance in dry and regularly ventilated
room. Allowed ambient temperature depends on
the model (class) of the appliance and is stated
on the rating plate of the appliance.
Never place the appliance near heat emitting
devices (e.g. cooker, radiator, water heater or
similar devices) and do not expose it to direct
sunlight.
The appliance should be positioned at least 3 cm
away from the electric or gas cooker and at least
30 cm away from the oil or coal stove. If this is
not possible, use an appropriate insulation.
Behind the appliance there should be free space
at least 200 cm² wide and above the appliance
the high kitchen units should be at least 5 cm
away from the appliance in order to assure
adequate ventilation of the condenser unit.
Class
Ambient temparature
SN (sub-normal)
from + 10°C to + 32°C
N (normal)
from + 16°C to + 32°C
ST (sub-tropical)
from + 18°C to + 38°C
T (tropical)
from + 18°C to + 43°C
Connection to Power Supply
Connect the appliance with the cable and plug to
the power supply socket outlet with a ground
terminal (safety socket).
Required nominal voltage and frequency are
indicated on the rating plate.
The connection to the mains supply and earthing
have to be made according to current standards
and regulations. The appliance resists temporary
voltage tolerance up to -15 to +10 %.