Installing the chimney

The chimney is inserted into the hood body and fastened with the suspensi-
on angles to the wall under the room ceiling.

Set the suspension angles to the
width of 26 cm with the screws
(E).

Fasten the suspension angles with
the angle cover facing upwards
with wall screws and dowels. Mo-
unt the angle directly under the
ceiling so that the chimney is
flush with the ceiling.

Insert the chimney into the groove
between the housing and the
glass shelf with the lower edge on
the hood body.

Extend the upper chimney up-
wards and screw tight to the sus-
pension angles with the screws (F).

Screwing the control element tight

Reach through the right-hand side
of the opening at the bottom of
the hood body and tighten the
control element with the knurled
screws.

Make sure that all the control buttons protrude slightly forwards out of the
chimney.

Inserting the metal fat filters

Before you install the filters again, you should read off the serial number
and the model designation on the rating label and enter them on page 16.

Only appliances with recirculation mode

Place an activated charcoal filter
in each filter cover and secure
with the holders.

All appliances:

Mount both filter covers. To this
end, insert the two brackets of
one cover into the openings provi-
ded in the lamp holder, press the
filter upwards and then push in-
wards until it is firmly in position.

Mounting the ornamental glass

Undo the fastening screws on the
holders for the ornamental glass
and loosen the holders.

Insert the ornamental glass into
the holders from above and
tighten the screws slightly.

Carefully tighten the fastening
screws without using any force.

Danger! 

Do not tighten the screws too much. If the glass is under

stress, it might possibly shatter and cause injury.

KD 965.1 / KDEM 965.1

19

Содержание KD 965.1

Страница 1: ... for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Instruções de uso e de montagem KD 965 1 KDEM 965 1 537 517 G61 ...

Страница 2: ...s and functions For operating your cooker hood For operating the hood with stoves and heating appliances with a naked flame General advice 13 Your appliance at a glance 14 Using the hood 14 Before using your appliance for the first time Switching the lighting On Off Switching on the ventilation Changing the ventilation setting Switching the ventilation off Switching on the delayed stop time Cleani...

Страница 3: ... used simultaneously in rooms where a negative pressure of 0 04 mbar is not exceeded This ensures that the fumes from the stove are not sucked back into the room This can be achieved if there are non airtight openings in windows and doors ventilation wall boxes supplying extracting air or other technical devices e g interlock devices so that a sufficient supply of combustion air can flow back into...

Страница 4: ...he hood in the settings 2 to 4 after 10 minutes After switching the hood on press the respective setting button a se cond time With the timer activa ted the control light of the setting selected flashes Press the button 0 1 to switch off the hood before the time lapses Cleaning interval for the fat filters After about 30 hours of operation all the control lights flash at the same time to remind yo...

Страница 5: ...re with the holders Insert both filters again To this end insert the two brackets of one cover into the openings provided in the lamp holder press the filter upwards and then push inwards until it is firmly in position If the control lights still flash when the hood is used for the first time af ter cleaning press one of the lower three buttons The counter for the operating hours is then reset to ...

Страница 6: ... defective Pull out plug or switch off fuse Call Customer Service Halogen lighting does not work Lamp defective Replace lamp LED does not work LED defective Call Customer Service Performance of the cooker hood is re duced Filters very clogged Replace filters Several LEDs flash Not a defect see Cleaning the metal fat filters Rating label The rating label can be seen when you have removed the fat fi...

Страница 7: ...enclosed dowels and screws are suitable for walls made of perfora ted bricks or concrete bricks which are 20 mm thick For solid concrete walls you must use special concrete dowels from a specialist store For solid wooden walls you must use wood screws of sufficient thick ness and length Electric connection The hood is fitted with a normal mains plug and there should therefore be a socket outlet 23...

Страница 8: ...y The chimney consists of two parts The upper part has ventilation slits the lower part recesses for the control buttons The recesses for the control but tons must always be at the bot tom The chimney parts can be pulled apart and pushed together again as required Recirculation mode The ventilati on slits must be at the top Extraction mode The ventilation slits must be at the bottom so that they a...

Страница 9: ...he control buttons protrude slightly forwards out of the chimney Inserting the metal fat filters Before you install the filters again you should read off the serial number and the model designation on the rating label and enter them on page 16 Only appliances with recirculation mode Place an activated charcoal filter in each filter cover and secure with the holders All appliances Mount both filter...

Страница 10: ...pe must not exceed 2 5 m The pipe must be heat insulated or an air trap seal must be installed Extraction into an existing exhaust shaft The exhaust air must only be introduced into an existing exhaust shaft if this is insulated against damp and is not already used for fuel purposes Have the chimney sweep responsible approve the use of the shaft Please note If the extraction channel is led through...

Отзывы: