background image

18

ENG 

1

150/125 mm reduction.

1 Anti-recoil 

valve.

2

Supports for tubecover.

2

Supports hall.

6

Wall plugs (Ø8 x 40).

6

Long bolts (Ø5 x 45).

4

Wall plugs (Ø6 x 30).

4

Long bolts (Ø4 x 30).

2

Washers (Ø6.4 x Ø18).

2

Washers (Ø6.4 x Ø12).

2

Screws (Ø3.9 x 13).

4

Screws M4 x 12.

2

Clips.

Fig. 1 (Page 19)
On installing the kitchen hood make sure
that the Safety Instructions set out on page
14 are complied with.

To obtain optimum performance, the external
duct must not be more than FOUR METRES
LONG, have no more than two 90° angles and
its diameter must be at least Ø120.
1) Using the attached template, trace and drill
the points for fitting the wall plugs onto the wall
(P) (Ø8 x 40) and (J) (Ø6 x 30).     
2) Attach the Supports (O) to the wall using the
long bolts (Q) (Ø 5x45) and the support (H)
with the long bolts (I) (Ø 4x30), as in figure 1.
3) Fit the support (O) to the body of the hood
using the long bolts (L) (M4 x 12).
4) Trace the location of the wall plugs (R) (Ø8
x 40), through the inside of the kitchen hood.
5) Take the kitchen hood off.
6) Drill into the wall and fit the wall plugs (R)
(Ø8 x 40).
7) Hang the kitchen hood; tighten the screws
(M) (M4 x 12) with the washers (A3) (Ø6.4 x
Ø12) and the long bolts (S) (Ø5 x 45) with the
washers (T) (Ø6.4 x Ø18).
8) Mount the tubecovers, attaching the lower

one to the support (H) as per the detail in figure
1. Lift the upper tubecover up to the desired
height and mark its shape on the wall. Remove
the tubecovers.
9)  Fit the clips (F) to the support (C). 
10) Centre the support (C) around the shape
marked; trace and drill the fixing points for the
wall plugs (E) (Ø6 x 30). Attach the support (C)
with the long bolts (D) (Ø4 x 30).
11) Fit the part (A) if the inner tube (not
supplied) is Ø150 or (A) + (B) if it is Ø120.
12) Attach the inner tube with a clamp (not
supplied) to (A) or (B) as the case may be.
13) Once the inner tube has been fitted, fit the
lower tubecover around the extractor fan outlet
and attach the upper tubecover with the screws
(G) (Ø3.9 x 13).

When exterior gas extraction is not possible,
then the kitchen hood may be set to purify the
air by recycling it through active charcoal
filters.
The active charcoal filters have an active life of
between three to six  months, depending on
the individual  conditions of use. These filters
cannot be washed nor regenerated. They must
be replaced once their useful life comes to an
end.

Fig. 2 (Page 19)

1) Fit  nutsupport (G) to the body of the kitchen
hood.
2) Attach the supports (B) with the screws (E)
(M4 x 12) onto the nuts (G).
3) Mount the charcoal filters (A) introducing the
anchorages into the grooves of the supports
(B).  
4) Remove the tubecovers (H). Use the wall
plugs and the previously installed upper
tubecover's support (I) long bolts (D) (Ø4 x 30)
to fix diffuser into the wall (C). 
5) Connect the diffuser base (C) to the motor
exit via the inner tube (not supplied). Use
clamps (Not supplied). Fit the tubecovers (H)
again. 

Active charcoal filters  (Optional)

Installation

Accesories supplied

Manual DS KPB.qxd  27/02/2003  11:58  PÆgina 18

Содержание KD 646.1 E

Страница 1: ...allation Instructions d utilisation e avis de montage Instruηυes de uso com indicaηυes para montagem Istruzioni di uso e di montaggio Bruks och monteringsanvisningar Gebruiksaanwijzing en montagehandleiding Εγχειριδίου με τις Οδηγίεσ Χρήσεωσ KD 646 1 E KD 946 1 E Manual DS KPB qxd 27 02 2003 11 57 PÆgina 1 ...

Страница 2: ...sufficient ventilation Excessive fat accumulation in the kitchen hood and metal filters is a fire risk and may also cause dripping therefore the inside of the kitchen hood and the metal filters must be cleaned at least once a month The lower part of the kitchen hood must be fitted at least 50 cm over electric hobs and 65 cm over gas or mixed hobs FOLLOW THE MANUFACTURER S MINIMUM RECOMMENDATIONS N...

Страница 3: ...vers Switch on the extractor fan a few minutes before you start to cook in order to ensure that a steady air flow has been established before fumes appear Allow the extractor fan to run for several minutes after you have finished cooking between 3 to 5 minutes in order to expel all the grease from the outlet duct This prevents the return of grease smoke and smells Instructions for use Description ...

Страница 4: ...ce blackening it although this will not affect its fat retention capacity Once clean leave them to dry off and then fit them onto the kitchen hood Proceed as follows Unscrew the lamp cap trimming cover Change the broken burnt out lamp Maximum lamp power is 20 W G 4 Screw in the lamp cap trimming cover Cleaning and maintenance _________________________________________________________ Problem solvin...

Страница 5: ...Network Tension V Network Frequency Hz Lights Motor Power W Motor Volume 214224DS 220 240 50 2 x 20 250 800 m 3 h KÜPPERSBUSCH reserves the right to make changes and corrections to its products as it deems necessary without altering their basic characteristics Manual DS KPB qxd 27 02 2003 11 58 PÆgina 17 ...

Страница 6: ...e on the wall Remove the tubecovers 9 Fit the clips F to the support C 10 Centre the support C around the shape marked trace and drill the fixing points for the wall plugs E Ø6 x 30 Attach the support C with the long bolts D Ø4 x 30 11 Fit the part A if the inner tube not supplied is Ø150 or A B if it is Ø120 12 Attach the inner tube with a clamp not supplied to A or B as the case may be 13 Once t...

Страница 7: ...19 ENG FIG 1 FIG 2 Manual DS KPB qxd 27 02 2003 11 58 PÆgina 19 ...