24
Water outlet hose connection
The end of the drain hose can be connected in the following
ways:
1. To the sink outlet siphon, securing it if necessary with a
clip.
Attention!
Our appliances are supplied with a security
device to protect against the return of dirty water
back into the machine.
If the siphon of your sink has a "no return valve"
incorporated this can prevent the correct draining
of your dishwasher. We advise you therefore to
remove it.
2. Hooked over the edge of the sink using the special
curved plastic guide (if provided).
3. To a stand pipe provided with vent-hole, minimum internal
diameter 4 cm.
The waste connection must be at a height of between 30 cm
(minimum) and 100 cm (maximum) from the bottom of the
dishwasher.
The drain hose can face either to the right or left of the
dishwasher
Ensure the hose is not bent or squashed as this could
prevent or slow down the discharge of water.
If you use a drain hose extension it must be no longer than 2
metres and its internal diameter must be no smaller than the
diameter of the hose provided.
Likewise the internal diameter of the couplings used for
connections to the waste outlet must be no smaller than the
diameter of the hose provided.
Electrical connection
Before plugging the appliance into the wall socket, make
sure that:
1. The mains voltage corresponds to the voltage given in
the "Technical specifications".
2. The meter, fuses, mains power supply and wall socket
can all take the maximum load required.
Make sure that the socket and plug are compatible
without having to use any type of adaptor. If necessary,
have the domestic wiring system socket replaced.
Safety standards require the appliance to be
earthed.
The manufacture accepts no liability for failure to
observe the above safety precautions.
This appliance complies with the following E.E.C. Directives:
- 73/23 of 19.2.73 (Low Voltage Directive) and subsequent modifications;
- 89/336 of 3.5.89 (Electromagnetic Compatibility Directive) and subsequent modifications.
min 30 cm
max 100 cm
min 4 cm
Ø 21
Ø 18
CS09
2
3
1
max 100 cm
min 30 cm
max 100 cm
max 100 cm
+ 2 m max
CS10
Ø 18
Ø 21