Küppersbusch GKS 324.0 Скачать руководство пользователя страница 7

GKS 324.0/GKS 644.0 installation Natural gas

7

Technical data

Table of heat input

GKS 324.0

Total nominal heat input = 13307 Btu/h

Connected load of the appliance = 281 g/h

GKS 644.0

Total nominal heat input = 26273 Btu/h

Connected load of the appliance = 555 g/h

Cross calorific value and pressure

For Service: removal and replacement

[

The power supply and the gas supply should always be turned off during 
repairs or connection. To avoid potential safety hazards, make sure all 
installation, service and maintenance has been performed according to 
guidelines.

Removal:

– Press the cook top out of the worktop from below and remove.

Do not lift the cook top out of the recess with a screwdriver - You could 
damage the frame of the cook top. Press the cook top out of the recess 
from underneath to dismantle.

Replacement:

– Insert the rear edge of the 

cook top and carefully lower. 
At the same time press in 
the clip with both hands.

– Press cook top downward 

until it rests completely on 
the worktop.

– Place the burner cover, the saucepan support(s) and attachment carefully 

in the correct position.

– Insert plug into the socket.

Burner

Natural gas

Input

Btu/h

Simmering burner

large

3753

small

1024

Normal burner

large

6483

small

1297

High-speed burner

large

9554

small

1911

Type of gas

Caloric value H

s

 15 °C

pressure

MJ/m

3

Btu/foot

3

inch water 

column

Natural gas

40,1

1075

6

For technical information and/or 

replacement parts, please contact the

Küppersbusch Customer Care line 

at

1 - 800 - 459 - 0844

For the most efficient assistance, 

please have the Model and Serial 

numbers for the appliance available.

Содержание GKS 324.0

Страница 1: ...s for Natural Gas Unit GKS 644 0 GKS 324 0 072428 I21 USA Dear Consumer Please keep this manual in a safe place and pass it on to future reference Dear Installer Please leave this instruction with the...

Страница 2: ...chnician during normal business hours What Isn t Covered Service by an unauthorized agency will not be reimbursed Likewise the warranty doesn t cover any damage or repairs due to service performed by...

Страница 3: ...f turning on or shutting off gas to the appliance The maximum gas supply pressure in accordance with the inlet pres sure rating of the gas appliance pressure regulator supplied 6 inch water column is...

Страница 4: ...4 GKS 324 0 GKS 644 0 Installation Natural gas GKS 324 0 Appliance height GKS 644 0 Appliance height...

Страница 5: ...the appliance shall be conducted according to this installation instruction Absolutely no leakage should occur otherwise there is a danger of fire or explosion depending upon conditions Never use if...

Страница 6: ...down Place the burner cover the saucepan support s and attachment carefully in the correct position Pin up the control knobs Insert plug into the socket Initial start up Turn on the gas connection tap...

Страница 7: ...could damage the frame of the cook top Press the cook top out of the recess from underneath to dismantle Replacement Insert the rear edge of the cook top and carefully lower At the same time press in...

Страница 8: ...K PPERSBUSCH 112 N East Street Suite C Tampa Florida 33602 Telephone 813 229 7096 Fax 813 229 0982 Customer Care line 1 800 459 0844 www kuppersbuschusa com K PPERSBUSCH is a brand of Teka USA Inc...

Отзывы: