34
My Function
After having set cooking level and timer value for the zone, it is possible to memorize the settings
on the same zone.
• cooking stages of cooking zone (power)
• minutes and seconds of programmed cooking zone-related timer
• Keep warm function
• Automatic cooking function
•
To register a memory program for a cooking zone:
Action
Control panel
Display
Zone selection
Press key [
]
[ 0 ]
Set cooking level
Press key [ + ] or [ - ]
[ 0…9] or [ P ]
« Timer » selection
Press key [
] during 3s
Timer [ 00 ] min
Set the time
Press key [ + ] or [ - ]
[ 00 … 99 ]
Memorize the setting
Press key [
]
Double beep
Registering validation
If no memorising is made within timer validation the electronics returns in cooking position.
•
To activate the memory program for a cooking zone:
Action
Control panel
Display
Zone selection
Press key [
]
[ 0 ]
Activate the setting
Press key [
]
[ 0 … 9 ] or [ P ]
Timer [ 00 … 99 ]
Cooking zone runs with cooking level and timer value registered in memory program.
Operating time limitation
Each cooking zone is equipped with an operating time limitation: the cooking zone is
automatically switched off after a certain time without any change of settings. This time is varying
according to the selected power level as described in the table below.
Power level
Operating time
(hours)
1
8.7
2
6.7
3
5.3
4
4.3
5
3.5
6
2.8
7
2.3
8
1.9
9
1.5