background image

19

 

DESCRIPTION OF THE APPLIANCE 

Technical data 

Type 

Total power  Heating zone location 

Power 

Diameter 

EKEF8752.1 

EKE8752.XX 

8100 W 

Front left 

Rear left 

Middle 

Rear right 

Front right 

1200 W 
1800 W 

2200 / 1000 W 

1700 / 700 W 

1200 W 

155 mm 
190 mm 

220 / 145 mm 
190 / 120 mm 

155 mm 

Control panel 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

USE 

Sensitive touches 

Your ceramic hob is equipped with electronic controls with sensitive touch keys. When your 
finger touches the key, the corresponding command is activated. This activation is validated by 
a control light, a letter or a number in the display and/or a “beep” sound. 

Touch only one key on the same time. 

Display 

Display

 

 

 

Designation

  

 

 

Function 

 

 

 

Zero   

 

 

 

the heating zone is activated 

1…9   

 

 

Power level   

 

 

Selection of the cooking level 

 

 

 

Heat accelerator 

 

 

automatic cooking 

 

 

 

Error message 

 

 

Electronic failure 

 

 

 

Residual heat 

 

 

the heating zone is hot 

II 

 

 

 

Pause  

 

 

 

the hob is in pause 

Control light timer 

Timer Display 

[ + ] key 

On / Off 

Power Display 

Timer 

 key 

[ - ] key 

Extension 

zone 

Pause / 

Recall 

Locking key 

Содержание EKE8752.1ED

Страница 1: ...BEDIENUNGSANWEISUNG mit Montageanweisungen Instructions for use and installation Instructions d utilisation et d installation EKEF8752 1 EKE8752 1ED EKE8752 1F...

Страница 2: ...THER PROTECTIONS 18 DESCRIPTION OF THE APPLIANCE 19 TECHNICAL DATA 19 CONTROL PANEL 19 USE 19 SENSITIVE TOUCHES 19 DISPLAY 19 RESIDUAL HEAT INDICATION 20 STARTING UP AND APPLIANCE MANAGEMENT 20 BEFORE...

Страница 3: ...es off after using Keep an eye on the cooking using grease or oils that may quickly ignite Be careful not to burn yourself while or after using the appliance Make sure no cable of any fixed or moving...

Страница 4: ...drawer and the inferior part of the appliance is large enough 2 cm This is essential to guaranty a correct ventilation Never put any inflammable object ex sprays into the drawer situated under the vit...

Страница 5: ...hen your finger touches the key the corresponding command is activated This activation is validated by a control light a letter or a number in the display and or a beep sound Touch only one key on the...

Страница 6: ...use detergent which risks causing blue tinted colour on the glass surface Starting up Start up switch off the hob Action Control panel Display To start press the key 0 To stop press the key nothing or...

Страница 7: ...9 and time remaining Select the timer press once on timer key and simultaneously Stop the timer press on timer key 00 Confirmation press once on timer key and simultaneously 00 Automatic stop at the e...

Страница 8: ...7 7 Is blinking with A Switching off the automatic cooking Action Control panel Display Select the power press or 1 to 9 or Stop the cooking zone Press on key 0 Pause function This function brakes th...

Страница 9: ...can be locked with exception to the On Off key Locking Action Control panel Display To start press the key 0 Hob locking Press key during 2s Locking control light is on Unlocking Action Control panel...

Страница 10: ...h with washing up liquid diluted in a little water Then rinse with cold water and dry the surface thoroughly Highly corrosive or abrasive detergents and cleaning equipment likely to cause scratches mu...

Страница 11: ...stop doesn t start up The cooking zone is still hot H The highest power level is set 9 The cooking level was engaged with The symbol II displays Refer to the chapter Pause ENVIRONMENT PROTECTION The p...

Страница 12: ...ribed below Fitting installing Cut out sizes of the worktop A B E F H EKEF8752 1 798 mm 518 mm 750 mm 490 mm 44 mm EKE8752 1ED EKE8752 1F 800 mm 520 mm 750 mm 490 mm 44 mm Ensure that there is a dista...

Страница 13: ...ust respect the indications of the hood manufacturer In case of absence of instructions respect a distance minimum of 650 mm The connection cord should not be subjected after building in to any mechan...

Страница 14: ...Biphase 400V 2P N Put a bridge between terminal 1 and 2 Attach the earth to the terminate earth the neutral N to terminal 4 the Phase L1 to the terminals 1 or 2 and the Phase L2 to the terminal 3 Tri...

Отзывы: