background image

What to do if trouble occurs

 

Danger!

 The cooker hood may only be repaired by an authorised

technician.

 

Danger! 

For repair work the appliance must be disconnected from 

the power supply by pulling out the mains plug or unscrewing the 
household fuse.

First check whether there has been any operating error. You can deal with
some problems that occur yourself.

Problem

Cause Remedy

It is not possible to
switch off the cooker
hood.

Electronic component is
defective.

Pull out plug or switch off
fuse,
Call Customer Service.

Halogen lighting
does not work.

Lamp defective

Replace lamp.

LED does not work.

LED defective.

Call Customer Service.

Performance of the
cooker hood is re-
duced.

Filters very clogged.

Replace filters.

Rating label

The rating label can be seen when you have removed the fat filter or the
activated charcoal filters. Please make a note of the following data on the
rating label before or while installing the cooker hood in case you have to
consult our Customer Service:

Serial number:

Model designation:

Installation

 

Danger!

 The cooker hood may only be installed and the electrics

connected by a qualified technician.
Pay attention to the notes on safety on page 12!

 

Danger! 

For all installation and maintenance work the cooker hood

must be disconnected from the power supply. As the mains plug 
is no longer accessible after installation, you must switch off the
relevant household fuse.

Scope of delivery

The hood is delivered in a cardboard box. The box contains:

chimney, drill hole template, fixings, activated carbon filter holder, hood with
motor and metal-mesh grease filter
recirculated air deflector (for use only in recirculation mode).

Dimensions for installation

Installation preconditions 

Please also observe the notes on extraction paths on page 18.

Walls suitable for mounting

The cooker hood can be mounted directly on the wall or on a steel rear panel.

The fitter is always responsible for selecting the correct fastening materi-
al. The fastening method must be suitable for the weight of the hood.

The enclosed dowels and screws are suitable for walls made of perfora-
ted bricks or concrete bricks which are  20 mm thick. 

For solid concrete walls you must use special concrete dowels from a
specialist store.

For solid wooden walls you must use wood screws of sufficient thick-
ness and length.

KD 934.1

KD 634.1

KD 934.1 / KD634.1

15

Содержание D 633.0

Страница 1: ...ons for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje Inst...

Страница 2: ...urchased For claims under guarantee the sales receipt must be produced Contents Safety instructions 12 For connections and functions For operating your cooker hood For operating the hood with stoves a...

Страница 3: ...that the fumes from the stove are not sucked back into the room This can be achieved if there are non airtight openings in windows and doors ventilation wall boxes supplying extracting air or other te...

Страница 4: ...in to switch the lighting off Switching on the ventilation Press button 0 1 in order to switch the hood on Changing the ventilation setting You can change the ventilation set ting you have selected wh...

Страница 5: ...n recirculation mode change the activated carbon filter mat whenever necessary To refit the filters place in the slot at the rear and push up They will then click into place Changing the activated cha...

Страница 6: ...d the electrics connected by a qualified technician Pay attention to the notes on safety on page 12 Danger For all installation and maintenance work the cooker hood must be disconnected from the power...

Страница 7: ...the distance between the hood and the cooker must be at least 650 mm Establish the chimney length accordingly The wall mounting must be aligned with a spirit level Correct alignment of the hood is on...

Страница 8: ...ctor openings are in line with the venting slots The open side of the deflector must adjoin the chimney The hood and vent opening or air deflector in recirculation mode must be connected via exhaust d...

Страница 9: ...pe must not exceed 2 5 m The pipe must be heat insulated or an air trap seal must be installed Extraction into an existing exhaust shaft The exhaust air must only be introduced into an existing exhaus...