10/22

T1-88-05

Internal use only

Configuration: LISA (Bora)

Standard procedure for manual configuration:

Before you can begin with configuration, you will need to
remove all the pans from the cooking zones.

You need a suitable induction cooking pan which covers
at least 80% of the biggest diameter of a cooking area
(e.g. inductor 200mm > pan size > 160mm).

Configuration can be triggered within 2 minutes of swit-
ching on the power supply. The controls are not switched
on when you do this. The displays will all remain dark.

1. Press the minus key (5) and keep it pressed.

2. Press all the select keys anti-clockwise, beginning with

the cooking zone (9) at the front right. A buzzer will
sound in confirmed each time a key is pressed; a faulty
entry is acknowledged with a double buzzer signal. In
this case entry to the service menu will need to be
repeated.

In the cooking zone displays, a "C" will show for cooking
zones that have not been configured and *-* will show for
configured cooking zones.

The cooking zone to be configured can be selected with
the cooking zone selection key. When a key is pressed,
the "C" in the corresponding display will start to blink.

Cooking zones that have already been configured cannot
be configured again. If configuration is faulty, e.g. becau-
se the pan was placed on cooking zone other than the in-
tended zone, all the configurations will need to be deleted
again.

To do so, press the minus key ( 5 ) and the plus key ( 6 ) for at least 2 seconds.

While you are pressing, an "E" will appear on all the cooking zone displays. The "E" in the cooking zone
displays will blink until all the induction modules have been returned to their initial state, then the display
will switch to "C". The cooking zones must now be configured again.

A pan must now be placed on the relevant cooking zone within 20 seconds, so that the induction module
can recognise the corresponding position. The display will show "-" once the position has been recog-
nised. Under no circumstances may two pans be placed on the cooking zones at the same time, since
in this case they will both be allocated to one cooking zone. If this should happen, all the configurations
will need to be deleted and restarted from the beginning again.

The procedure is repeated for all the cooking zones, until the last cooking zone automatically leaves the
configuration menu after configuration. The configuration menu can also be exited by pressing the power
key. If a key is pressed the menu will be exited after two minutes.

Sensor keys

1 reduce ventilation
3 increase ventilation
4 hob on/off
5 reduce cooking level timer value
6 increase cooking level timer value
9 selsct cooking zone

Содержание T1-88-05

Страница 1: ...ng all zones correctly the configuration menu will be exited automatically The cooking zone will turn off By touching the on off key the cooking zone is then switched on again and the display will sho...

Страница 2: ...u are pressing 5 The E in the cooking zone displays will flash the display will then switch to C The cooking zones can now be newly configured Configuration 1 Use a magnetic based pan with a diameter...

Страница 3: ...ith your fin ger when this is done the setting on the display power level will gradually change When you put your finger on the sensor field and then move it to the left or right the display setting w...

Страница 4: ...appear in the display 4 Touch rear left cooking zone regulation display as a touch key until blinking C appears Then put a pot on the front left zone for correct configuration will appear in the disp...

Страница 5: ...edure is now complete The cooking hob will switch off 7 Check up In all cooking zone displays 0 will appear in the dis play when switched on to indicate that the configu ration has been completed corr...

Страница 6: ...combination with the pressed special func tion key The next key must be pressed within 1 sec of the last key being pressed each time As soon as the sequence or the timing is not obser ved a short dou...

Страница 7: ...iguration the sign appears in the display 6 Use front right Select Plus key until blinking C appears Then put a pot on the front left zone For correct configuration the sign appears in the display The...

Страница 8: ...rt Disconnect the cooking hob from power supply and put it on again or switch off the circuit breaker and switch it on again Make sure NOT to use the on off key now start configuration within 2 minute...

Страница 9: ...4 Press Plus key for rear zone until blinking C appears Then put a pot on the rear zone For correct configuration the sign appears in the display The configuration procedure is now complete The cooki...

Страница 10: ...If configuration is faulty e g becau se the pan was placed on cooking zone other than the in tended zone all the configurations will need to be deleted again To do so press the minus key 5 and the pl...

Страница 11: ...ion menu see specifica tion for manual configuration C blinks A blinking C shows that this cooking zone is ready to be configured No error user is in the configuration menu Place a suitable pan on IHE...

Страница 12: ...king zone will be ready for use again If the error occurs regularly the pan will have to be removed 2 If the error also occurs without a pan or with a pan that is clearly in good working order the IHE...

Страница 13: ...IHE Defect component IGBT on one of the affected IHEs Defect or missing LIN bus cable between CU and IHE Multimeter diode test measurement see p 22 Replace IHE Replace faulty CU Check or replace the L...

Страница 14: ...ponent fault ca 47 kW Connect the power supply properly Replace the touch control Multimeter diode test measurement see p 22 Replace IHE Replace faulty CU Check or replace the LIN bus cable Faulty pan...

Страница 15: ...cont rols switch off after 10 sec Liquid or cookware on the glass above the controls Clean the glass ceramic surface Power setting back to 0 IHE component fault Replace IHE L No error Childproof lock...

Страница 16: ...ion menu see specifica tion for manual configuration C A steady C shows that this cooking zone is ready to be configured No error user is in the configuration menu Place a suitable pan on IHE C blinki...

Страница 17: ...error also occurs without a pan or with a pan that is clearly in good working order the IHE will need to be replaced as a hardware error will have occurred E 4 Unconfigured IHE or no com munication be...

Страница 18: ...e configuration Delete all the configurations and con figure E H Festwiderstandserkennung Findet nach Aktivierung der Koch stelle innerhalb von 5 Minuten kein Temperaturwechsel an der Koch stelle stat...

Страница 19: ...ol Er 22 Key interpretation defect touch control switches off after 3 5 7 5 sec Short circuit or interruptions in the key interpretation Replace the touch control Er 03 or Permanent key operation cont...

Страница 20: ...20 22 T1 88 05 Nur zum internen Gebrauch Fuse track...

Страница 21: ...the output the TC will be in working order If 230V are not applied at the output the IGBTs of the IHEs will need to be checked see IHE short circuit test replace the CU and defect IHE If the test show...

Страница 22: ...y IHE short circuit test In the event of a short circuit the defect hob and the connection compon ents will need to be replaced Pull out the plug to measure the hob Select the diode tester on the mult...