Instructions for assembly
42
GB
e
h
7.8 7-pole fan plug connector
DANGER
Risk of electric shocks
The fan plug connection must be made befo-
re the mains connection!
The appliance must be cut off from the
electricity supply before the plug retainer
is opened again. The appliance may only
be connected to the mains once the plug
connection has been made.
The hob may only be switched on when the
fan mating connector has been attached and
the plug retainer closed.
Procedure
Connect the two 7-pole plus for the fan connection.
Open the plug retainer on the 7-pole plug (fan) of the hob
and attach the 7-pole fan mating connector (e) until it is
securely engaged. Then close the plug retainer again.
7.9 4-pole plasma fi lter plug connector (optional)
DANGER
Risk of electric shocks
The plasma connection must be made befo-
re the mains connection!
The plug retainer and protective cover may
only be removed when the relevant plasma
fi lter (optional) has been approved.
Procedure
Open the plug connections on the 4-pole plug (plasma) of
the hob and remove the protective covers. Attach the plug
to the 4-pole mating plug of the plasma fi lter (g) until it has
fi rmly engaged.
Then close the plug retainer again.
DANGER
Risk of electric shocks
The appliance must be cut off from the
electricity supply before the plug retainer
is opened again. The appliance may only
be connected to the mains once the plug
connection has been made.
The hob may only be switched on when the
Plasma mating connector (optional) has
been attached and the plug retainer closed.
If the plasma fi lter is removed again at a later
point in time, the 4-pole plug of the hob must
be safely reconnected to the protective cover
and the plug retainer.
Содержание KMI9850.0
Страница 152: ...K06 180211 01 ...