background image

is coloured blue must be connected to the terminal
which is marked with the letter N or coloured black; –
the wire which is coloured brown must be connected
to the terminal which is marked with the letter L or
coloured red.
When making the electrical connections, check that
the voltage values correspond to those indicated on
the data plate inside the appliance itself. In case your
appliance is not furnished with a non separating
flexible cable and has no plug, or has not got any other
device ensuring omnipolar disconnection from the
electricity main, with a contact opening distance of at
least 3 mm, such separating device ensuring
disconnection from the main must be included in the
fixed installation. If your unit features a power lead and
plug, position this so the plug is accessible.
Always switch off the electricity supply before carrying
out any cleaning or servicing operations on the
appliance.

USE

----------------------------------------------------

Avoid using materials which could cause spurts of
flame (flambées) near the appliance.
When frying, take particular care to prevent oil and
grease from catching fire. Already used oil is especially
dangerous in this respect. Do not use uncovered
electric grates.
To avoid possible risks of fire always comply with the
indicated instructions when cleaning anti-grease filters
and when removing grease deposits from the
appliance.

MAINTENANCE

----------------------------------------------------

Thorough servicing guarantees correct and long-
lasting operation.
Any fat deposits should be removed from the appliance
periodically depending on amount of use (at least
every 2 months). Avoid using abrasive or corrosive
products. To clean painted appliances on the outside,
use a cloth dipped in lukewarm water and neutral
detergent. To clean steel, copper or brass appliances
on the outside, it is always best to use specific
products, following the instructions on the products
themselves. To clean the inside of the appliance, use
a cloth (or brush) dipped in denatured ethyl alcohol.

DESCRIPTION

----------------------------------------------------

The unit can be found in filtering hoods, ducting hoods

or in hoods with an outside motor. In the Filtering version
the air and the kitchen fumes that are conveyed by the
apparatus are depurated by the charcoal filter and put back
into the room through the small grilles of the ventilation flue
(Fig. 1). ATTENTION: When using the filtering version, a
charcoal filter and an air baffle (Fig. 1A) must be used,
which placed at the top of the structure, allows the air to
recycle back into the room.  In the  Ducting version,
cooking vapours and odours are conveyed straight outside
by a disposal duct which passes through the ceiling (Fig.
2). In the hoods with an outside motor (Fig. 3), a vacuum

suction unit must be connected; this exhaust will operate
separately, conveying the exhaust air through the unit.
Only use vacuum units suggested in the original
catalogue.

INSTALLATION

----------------------------------------------------

ATTENTION: Two persons are required for proper

installation; the unit should be installed by a qualified
operator. Also follow carefully each step of the
assembly instructions, and once installation has been
completed, make sure that the hood is firmly secured
in place.

To facilitate installation, before starting remove the

grease filter: press inward on the clamp at the handle and
pull the filter downward (Fig. 4).

For assembling it is essential to: – Prepare the

connection to the mains within the telescopic flue. – If your
unit is installed in an ducting hood or in a hood with outside
motor, prepare the air exhaust hole.

When installing ducting hoods and hoods with outside

motor, to achieve the best possible conditions use an air
exhaust pipe
 that : is as short as possible, has a minimum
of curves (maximum angle: 90°), is made of a material that
complies with the standards (which vary from nation to
nation) and iv)  is smooth on the inside.  It is also advisable
to avoid any drastic changes in pipe section (diameter: 150
mm).

ASSEMBLING - Using the special drilling template,

drill the holes for fixing to the ceiling on the vertical side of
your hob. Carefully observe all the indications for final
positioning of the apparatus. Take into account that one of
the template axes must correspond to the axis of the hood
controls. Fix the bracket to the ceiling using the screws and
screw anchors provided (Fig. 5). Be careful, because the
position of the bracket determines the final position of the
apparatus: the side with the slot B corresponds to the side
opposite the commands.
Ducting version and version with an external motor: Fix the
telescopic structure to the bracket by means of 4 screws
(provided), running the air evacuation pipe through the
telescopic structure and the electric power cable through
the special hole in the bracket (Fig. 6). Adjust the height of
the telescopic structure by means of the four retaining
screws C (Fig. 7), taking into account that the height of the
hood is 70 mm and that the distance between the hood and
the hob must be at least 650 mm (Fig. 8).  Take the upper
pipe (with the round slots) and fit it on the telescopic
structure with the slots facing downwards; fit the pipe to the
bracket with 2 screws (Fig. 9). Take the lower pipe and fit
it in the same manner as before; slide it to the top and stop
it in that position using a screw inserted in the hole of the
upper pipe as a catch (Fig. 10).
Mount the plate of the electrical system fixing it with 3
screws (Fig. 11).
Fit the hood to the telescopic structure by means of 4
screws (provided) – Fig. 12.
Through the openings D (Fig. 12) fix the air evacuation
pipe to the air outlet mouth of the hood.
Only for models with outside motor (Fig. 13): plug the hood
into the outside control unit using the special terminal
block: remove wire clamp A and lid B from the wiring
junction box; secure the wire connecting the control unit to