2
Gas Installation Requirements
This appliance shall be installed by an authorized person and installed in accordance to
The manufactures installation instructions. IMPORTANT: This Appliance must be installed in strict
Compliance with all Federal, State and Local laws (Where applicable) In the absence of local codes, the installation must
conform to American
National Standards, National Fuel Gas Code ANSI Z223.1 – Latest edition ** or B149.1
If local code permits, a flexible metal appliance connection with the new AGA or CGA certified
Design, max. 5 feet (1.5 mm) long, ½ “I.D. recommended for connecting this Cooktop to the gas supply
line. Do not bend or damage the flexible connector when moving the Cooktop. The pressure regulator has ½ “
female pipe thread. You will need to determine the fitting required, depending on the size of your gas supply line,
the flexible metal connector and the shutoff valve.
The appliance and its individual shutoff valve must be disconnected from the gas supply piping system for testing. The
maximum pressure applied to the unit for testing must not exceed ½ p.s.i (3.5kPa). The minimum pressure required to test
the system must be at least 1” Water column (249 Pa) above the inlet specified manifold pressure to the appliance. The
maximum inlet gas supply pressure to the regulator must not exceed 20” Water column (5 kPa).
The supplied regulator must be installed between the main gas supply line and the Cooktop. The regulator must be set to
the proper gas supply. The gas pressure required on this unit is 4” Water column (Natural) and 11” Water column (Liquid
Propane). The regulator is set to NAT from the factory.
This unit is shipped from the factory set for NATURAL GAS. This unit is supplied with a conversion kit to convert this
unit to Liquid Propane (L.P.). You will find this kit along with the installation instructions and the operation booklet.
If the unit is converted it is recommended that you save all the Natural gas orifices in the event that the unit is to be
converted back to natural gas In the future.
WARNING!
Only a licensed and certified Gas installer should attempt the conversion.
Electrical Installation Requirements
This appliance, when installed by a licensed and certified electrician must be electrically grounded in accordance
With all Federal, State and Local laws (Where applicable). In the absence of local codes, the installation must conform
To the
National electrical Code, ANSI/NFPA 70.
This unit requires a three-prong 120 volt, 15 amp 60 Hz wall connection. The unit is supplied with a 5 foot three
Prong plug. The outlet must be grounded and polarized. A non-polarized outlet may cause erratic operation of the
Ignition system.
WARNING!
Electrical grounding instructions: This appliance is equipped wit h a three prong grounded plug for your
protection against shock hazard and should be plugged directly into a properly grounded receptacle. Do not cut or remove
the grounding prong from this plug.