6
Gas hob instructions for use
Installation and Operation
3 Installation and Operation
3.1 Installation and operation safety
WARNING
Fatal injury caused by explosive gas
●
Gas connections must all be installed by a registered gas installer.
●
Only operate gas hobs in a well-ventilated, sufficiently large room (at least 20 m³) or install
a mechanical ventilation device, e.g. a cooker hood. Take account of ventilation when
making constructional changes to buildings.
Fatal injury caused by fire
●
The packing elements (carboard, bags, polystyrene, nails) must not be left with the reach
of children as they are potential sources of danger.
●
Never install gas hobs near flammable items, e.g. decorations.
●
Use heat-resistant wall connection strips which do not rest more than 30 mm on the
worktop.
●
The appliance can be installed with just one lateral wall (to the right or left of the hob),
higher than the hob and positioned at a minimum distance as described in the tale below.
MEASUREMENTS TO OBSERVE (in mm)
A
B
C
D
E
F
1F - 2F (30)
282
482
59
59
100 min.
70 min.
Fatal injury caused by electricity
●
Cables may not come into contact with hot parts.
●
Do not bend cables or install them direct on sharp edges.
●
Check electrical connections, see Section 6 “Technical Data”.
Содержание GKS3820.0ED-HK
Страница 20: ...Version 1 2018...