Service Manual EMWK 870.1
9
For internal use only
1
Display .30 can be changed by turning time knob.
3.3
Terminate Test Procedure
•
After 40 sec. without pressing a key, the test procedure is exited!
•
By interruption of mains voltage.
3.4
Fault Indications
Key Depressed
Symbol Indication
Indication
90 W
90
11.11
180 W
180
22.22
360 W
360
33.33
600 W
600
44.44
800 W
800
55.55
Timer
Timer
66.66
Clock
All Symbols
77.77
Combi
Combi Mode Symbol
88.30
1
Convection Time
Convection Time
Memo
M1, M2
Stop
Buzzer
Start
No Symbols
Software Version
microwave module
Error Indication
Faults
Response of Microwave in case of Fault
Er3
Electronics overheated
(pcb temperature >85 °C)
Convection does not heat up, blower
running. After cooling-off, the fault is
cancelled and microwave reheats.
Er9
Fault during ROM-check in
microwave module
After a Reset (e.g. power failure) there is a
ROM-Check. The fault is only indicated in
the module in which the fault actually
occurs.