8
Service Manual EMWK 870.1
For internal use only
3.
Test Procedures
3.1
Function Test
Warning!
Access only possible after short switch-off of mains voltage! Access within the next
2 minutes. Oven door may be open or closed!
1.
Start key
press once.
2.
Stop key
press twice.
3.
Timer key
press three times.
4.
All segments of the display light up, buzzer sounds.
5.
Door open or closed will start the testing procedure.
When pressing the keys described, the consumers are driven for the duration of 20 seconds.
3.2
Test Procedure Indication Test
Warning!
Access only possible after short switch-off of mains voltage! Access within the next
2 minutes. Oven door may be open or closed!
1.
Stop key
press once.
2.
Start key
press twice.
3.
Memo key
press three times.
4.
All segments of the display light up.
5.
Any key will start the testing programme.
Key Depressed
Symbol
Indication
Indication
Function
(consumer)
Relay
Start
800
A6. A7
MW - 800W
K6 /K7 /K2
MW- Start
Timer
Timer
A4
Convection
K4
Clock
Clock
A2
Oven Light
Blower
K2