20
EKI 307
Installation
Note
The KÜPPERSBUSCH induction hob may only be built-in in accordance
to the instructions included in this manual:
–
on a cover plate
– above a KÜPPERSBUSCH electrical built-in oven with cooling fan
– above a drawer, only with acc. no. 136.
The KÜPPERSBUSCH induction hob must not be installed above a
dishwasher.
In case of a failure to observe these instructions, KÜPPERSBUSCH shall
decline any liability and the approved marks of conformity become
invalid!
Notes for fitting
■
Should the built-in cooking surface be operated with an oven installed
underneath, only Küppersbusch built-in baking ovens with appliance cooling
are permitted.
■
If the cooking surface is built in above a bottom cupboard a cover plate has
to be built into the kitchen cupboard.
■
Possible thickness of worktops:
above an oven installed underneath: 40 - 50 mm
above a cover plate: 30 - 50 mm.
If these dimensions are not respected the electronics of the hob can
overheat!
We recommend installation similar to that illustrated below.
■
The distance to mounted
cupboards should be for
technical reasons at least
300 mm.
■
Cooker hoods or wall
cupboards mounted above
the hob must be installed
with a minimum distance of
650 mm to the hob.
■
No cross-bars may be in the
area of the cut-out
underneath. They have to be
reduced at least to the
opening size of the worktop.
■
The plastic finish or the veneer of built-in kitchen furniture must have been
produced using a heat-resistant adhesive (100 °C).
Dimension drawing for the installation in the induction hob:
■
The distances of the
opening to the wall for
the front, the back and
the side (see last
drawing) have to
correspond to the
dimension drawing!
■
A corner moulding of
solid wood may be fitted
to the worktop at the
back of the hob provided
that the minimum
clearances are
maintained.
■
The working surface must
be installed absolutely
horizontally and the opening must be cleanly cut.
We recommend to seal the cut sections of the worktop for built-in
dishwashers and oven hobs with a water-repellent protection paint.
■
Each time the appliance is removed from the worktop, replace the seals.
■
In the case of ceramic-tiled worktops it is necessary to provide an additional
seal with the aid of a permanently elastic sealing compound. Such sealing
compound can be purchased as KÜPPERSBUSCH spare part No. 53 55 69.
■
A ventilation slit of at least 7 mm must be provided above the panel in every
method of installation. Ventilation openings are to be provided in the back
of the cupboard.
Cold air is drawn in through the front ventilation slit. The heated air escapes
through the ventilation openings in the rear. An air channel to be installed
(see following descriptions) prevents the heated airflowing back to the cold
air intake side.
Installation of the cooking surface
– Insert ventilation slits (see dimension drawing).
– Cutting-out the opening.
– Seal the edges of the worktop.
– Install the working top horizontally.
Enclosed to the appliance are two foam mouldings. Which one has to be used
depends on the installation of the hob:
■
Above a cover plate:
Use foam mouldings with
50 mm height.
■
Above an oven installed
underneath:
Use foam mouldings with
20 mm height.
– Remove the protection tape on
the bottom of the appliance.
Aspiration
Venilation
All manuals and user guides at all-guides.com