Kuppersbusch EKE 81.2 Скачать руководство пользователя страница 10

20

EKE 81.2

Electrical connection

■ 

The built-in cooking area must be connected to the mains supply by 
a qualified electrician who is authorized to carry out such work. 

■ 

Both legal wiring regulations and the requirements of your local electricity 
supply board must be fully complied with.

■ 

When connecting the hob, a device must be provided which enables all-
pole disconnection of the hob from the supply with a gap construction of at 
least 3 mm. Circuit breakers, fuses and contactors are considered to be 
suitable disconnecting units.

■ 

When connecting and repairing the appliance disconnect it from the elec-
tricity supply with one of these devices.

■ 

Overall protection against electric shock must be ensured by the installation.

■ 

The earthed conductor lead must be sufficiently long so that, in the event 
of failure of the strain relief, it is not subjected to strain until after the live 
wires of the connection cable.

■ 

Any superfluous cable must be removed from the installation area beneath 
the appliance. See the illustration on page 18 for the position of the cable 
cut-out.

To connect the appliance, unscrew the switchbox cover on the underside of 
the appliance to access the terminal block. After connecting the appliance, re-
place the cover and secure the connection cable with the strain relief clamp.

■ 

The green-yellow earth conductor must be longer than the other wires.

Electrical connections  

Caution: 
Incorrect connection results in the total destruction of the power elec-
tronics.  

Electrical 
connection

Permanent connection by means of an oven connection 
socket.

Connection 
diagram

is depicted on the underside of the appliance, suitable for 
the various types of mains.

Connection data

Permanent connection 400 V 3 N 

~

 50 Hz 

   (AC 230 V in UK)
Voltage of heating element: 230 V
Total connection output: 7.6 kW
400 V 3 N 

~

 safety current 16 A

400 V 2 N 

~

 safety current 20 A

230 V 1 N 

~

 safety current 25 A

Connection cable at least of type HO5 VVF 

Length of cable as necessary.

(*) This type of electrical connection is not permitted by the SEV (Swiss As-

sociation of Electrical Engineers) in Switzerland.

Содержание EKE 81.2

Страница 1: ...ctions for use and installation instructions Instructions d utilisation et avis de montage Gebruiksaanwijzing en montagehandleiding Istruzioni di uso e di montaggio Instrucciones de uso y de montaje I...

Страница 2: ...lp prevent potential negative consequences for the environment and human health which could otherwise be caused by inappro priate waste handling of this product For more detailed information about re...

Страница 3: ...zones 2 Cooking setting display of the cooking zones 3 Sensor keys for cooking zones 4 Minus sensor 5 Plus sensor 6 Sensor lock 7 Sensor key ON OFF 8 Multi circuit key 9 Timer 10 Frying zone 11 Dual...

Страница 4: ...there are any pets in the apartment which could come near the hob ac tivate the lock Before first use Remove packaging and moving parts Before first use the cooking area should be cleaned with a damp...

Страница 5: ...ing level as soon as the set parboiling boost time has elapsed Activate the required cooking zone by means of its cooking zone sensor key Select the cooking level 9 with the minus sensor The automatic...

Страница 6: ...place a lid on the pan You will save a lot of energy by cooking in a closed pan Liquids and foods will only boil over if the temperature is too high For the cooking zones you can precisely set the tem...

Страница 7: ...if due to incorrect op eration or to non adherence to our instructions given under What to do if there is a fault You should always give the data on the rating plate to your service centre in case you...

Страница 8: ...ted by a panel which prevents inadvertent con tact with the live parts or connecting leads between the control unit and the hob unit It must not be possible to remove the panel without tools Any cooke...

Страница 9: ...careful not to pinch the connecting cable It is essential that the hob rests evenly in the opening since strain may cause the griddle hob to crack on being heated up F If the hob is not fixed tightly...

Страница 10: ...removed from the installation area beneath the appliance See the illustration on page 18 for the position of the cable cut out To connect the appliance unscrew the switchbox cover on the underside of...

Отзывы: