Kuma Stoves K-300 Скачать руководство пользователя страница 6

Section J-  Stove Maintenance Warnings 

 

DO NOT OVERFIRE THIS HEATER: 

EXCESSIVE TEMPERATURES CAN CAUSE THE  

STEEL PLATE TO WARP OR CRACK. 

 

 

*

CAUTION: 

 

 

Never use gasoline, gasoline-type lantern fuel, kerosene, charcoal 

 

 

lighter fluid or similar liquids to start or ‘freshen-up’ a fire in this 

 

 

heater.  Keep all such liquids well away from the wood stove while it is 

 

 

in use. 

 
 

*

CREOSOTE:  Formation and need for removal 

 

 

When wood is burned slowly, it produces tar and other organic vapors,  

 

 

which combined with expelled moisture forms creosote.  The creosote 

 

 

vapors condense in the relatively cool chimney flue of a slow burning fire. 

 

 

As a result, creosote residue accumulates on the flue lining.  When ignited, 

 

 

this creosote makes an extremely hot fire.  The chimney connector and  

 

 

chimney should be inspected at least once every two months during the  

 

 

heating season to determine if a creosote build-up has occurred.  If 

 

 

creosote has accumulated, it should be removed to reduce the risk of a  

 

 

chimney fire. 

 
 

*

DISPOSAL OF ASHES: 

 

 

Ashes should be placed in a metal container with a tight fitting lid.  The 

 

 

closed container of ashes should be placed on a non-combustible floor or  

 

 

on the ground, well away from all combustible materials, pending final 

 

 

disposal.  If the ashes are disposed of by burial in soil or otherwise locally 

 

 

dispersed, they should be retained in the closed container until all cinders 

 

 

have thoroughly cooled. 

 
 

*

USE OF GRATE IS NOT NECESSARY FOR PROPER OPERATION OF  

 

  THIS STOVE. 

 

Section K-  Proper Draft Information 

 
 

ACHIEVING PROPER DRAFT: 

 

 

Draft is the force which moves air from the appliance through the 

chimney.  The amount of draft in your chimney depends on the length of the chimney, 
local geography, nearby obstructions, and other factors.  Too much draft may cause 
excessive temperatures in the appliance and may damage the catalytic combustor.  
Inadequate draft may cause backpuffing into the room and plugging of the chimney or 
the catalytic.  Inadequate draft will cause the appliance to leak smoke into the room 
through the  

Содержание K-300

Страница 1: ...stove insert Under specific test conditions this wood stove has been shown to meet the U S Environmental Protection Agency s emission limits for residential wood stoves Please read this entire manual...

Страница 2: ...ice Department 5555 Pleasantdale Road Doraville GA 30340 Should the combustor become ineffective or require replacement please take extreme care to package the combustor in foam rubber or other soft m...

Страница 3: ...ng of the stove When refueling or rekindling a cool fire or a fire that has burned down to the charcoal phase operate the stove again at a medium to high burn rate about 15 20 minutes until a sufficie...

Страница 4: ...and inhibited Blowing air through combustors thereby removing fly ash Section H Operation and Maintenance RECOMMENDATIONS FOR BUILDING AND MAINTAINING A FIRE CAUTION HOT WHILE IN OPERATION KEEP CHILDR...

Страница 5: ...t 5 8 diameter 5 ft 2 Glass Gasket Window channel with adhesive 5 ft 3 Catalytic Gasket 1 16 x 3 8 ft 4 By pass Gasket 1 8 x 1 1 2 3 feet required SEE FIGURE 1 FOR LOCATIONS OF GASKET CATALYTIC REPLAC...

Страница 6: ...s accumulated it should be removed to reduce the risk of a chimney fire DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be p...

Страница 7: ...ve 8 flue 2 Floor protector 3 Chimney connector stovepipe 4 Chimney Refer to figure 5 a Chimney sections b Fire stop c Support box d Storm collar e Roof flashing f Chimney spark arrestor cap USE ONLY...

Страница 8: ...ces to combustibles NOTE Clearances may only be reduced by means approved by the regulatory authority INSTALLATION INSTRUCTIONS 1 Set the unit on the floor protector 2 Make sure the clearance from the...

Страница 9: ...ns that could affect draft such as chimney height geographical conditions location climate etc should be noted Contact your dealer with any questions PRELIMINARY CHECKS A preliminary check of the chim...

Страница 10: ...ion the faceplate back to the insert in the marked locations 3 Attach the faceplate pieces with supplied self drilling self tapping fasteners 4 Place fiberglass insulation around the faceplate back to...

Страница 11: ...stem This warranty does not apply in cases of abuse mishandling unauthorized repair or alterations failures or operating difficulties due to misuse accident improper installation improper maintenance...

Страница 12: ...2 gasket Wrap each pre wrapped unit with 1 8 X 2 gasket Typical Home Installation All KUMA stoves must be installed and operated in accordance with all local state and Federal laws codes and ordinanc...

Отзывы: