Section E-  Achieving and Maintaining  

 

 

 

Catalyst Light-Off 

 
 

Your KUMA stove is equipped with a by-pass plate that slides forward to allow 

the draft to escape up the chimney when the rod is pulled all the way forward.  This “by-
passes” the combustor for the purpose of (1) starting a fire, and (2) refueling.  This 
section describes the position of the by-pass for 3 different burning situations. 
 
 

1)  

START-UP:  

The by-pass rod would be pulled all the way out during start-up.  

It will remain open long enough to achieve a medium to high burn rate (about 15-20 
minutes).  It will also be necessary to “crack” the door to allow extra air during start-up.  
Check Operation Section ‘H’.  Usually a normal fire start-up to produce a good coal bed 
will produce sufficient temperatures to begin catalytic combustion. 
 
 

2

)  NORMAL OPERATION:  

After the start-up temperature is reached, the by-pass 

should be closed (pushed in).  This begins the flow of smoke and gases through the 
combustor.  The combustor will begin generating.  The by-pass is to remain closed 
during normal operation. 
 
 

3)  

REFUELING:

  The by-pass should be open (pulled out) during the refueling of 

the stove.  When refueling or rekindling a cool fire or a fire that has burned down to the 
charcoal phase, operate the stove again at a medium to high burn rate (about 15-20 
minutes) until a sufficient start-up temperature is reached. 
 
 

Section F– Catalyst Monitoring 

 

 

It is important to periodically monitor the operation of the catalytic combustor to 

ensure that it is functioning properly, and to determine when it needs to be replaced.  A 
non-functioning combustor will result in a loss of heating efficiency, and an increase in 
creosote and emissions.  Following is a list of items that should be checked on a periodic 
basis: 
 
 

*Combustors should be visually inspected at least three times during the heating  

 

  season to determine if physical degradation has occurred.  Actual removal of  

 

  the combustor is not recommended unless more detailed inspection is warranted 

 

  because of decreased performance.  If any of these conditions exist, refer to  

 

  Catalyst Troubleshooting Section ‘G’ in this owner’s manual. 

 
 

*You can get an indication of whether the catalyst is working by comparing the 

 

  amount of smoke leaving the chimney when the smoke is going through the  

 

  combustor and catalyst light-off has been achieved, to the amount of smoke  

 

  leaving the chimney when the smoke is not routed through the combustor (by-

 

  pass mode). 

Содержание K-300

Страница 1: ...stove insert Under specific test conditions this wood stove has been shown to meet the U S Environmental Protection Agency s emission limits for residential wood stoves Please read this entire manual...

Страница 2: ...ice Department 5555 Pleasantdale Road Doraville GA 30340 Should the combustor become ineffective or require replacement please take extreme care to package the combustor in foam rubber or other soft m...

Страница 3: ...ng of the stove When refueling or rekindling a cool fire or a fire that has burned down to the charcoal phase operate the stove again at a medium to high burn rate about 15 20 minutes until a sufficie...

Страница 4: ...and inhibited Blowing air through combustors thereby removing fly ash Section H Operation and Maintenance RECOMMENDATIONS FOR BUILDING AND MAINTAINING A FIRE CAUTION HOT WHILE IN OPERATION KEEP CHILDR...

Страница 5: ...t 5 8 diameter 5 ft 2 Glass Gasket Window channel with adhesive 5 ft 3 Catalytic Gasket 1 16 x 3 8 ft 4 By pass Gasket 1 8 x 1 1 2 3 feet required SEE FIGURE 1 FOR LOCATIONS OF GASKET CATALYTIC REPLAC...

Страница 6: ...s accumulated it should be removed to reduce the risk of a chimney fire DISPOSAL OF ASHES Ashes should be placed in a metal container with a tight fitting lid The closed container of ashes should be p...

Страница 7: ...ve 8 flue 2 Floor protector 3 Chimney connector stovepipe 4 Chimney Refer to figure 5 a Chimney sections b Fire stop c Support box d Storm collar e Roof flashing f Chimney spark arrestor cap USE ONLY...

Страница 8: ...ces to combustibles NOTE Clearances may only be reduced by means approved by the regulatory authority INSTALLATION INSTRUCTIONS 1 Set the unit on the floor protector 2 Make sure the clearance from the...

Страница 9: ...ns that could affect draft such as chimney height geographical conditions location climate etc should be noted Contact your dealer with any questions PRELIMINARY CHECKS A preliminary check of the chim...

Страница 10: ...ion the faceplate back to the insert in the marked locations 3 Attach the faceplate pieces with supplied self drilling self tapping fasteners 4 Place fiberglass insulation around the faceplate back to...

Страница 11: ...stem This warranty does not apply in cases of abuse mishandling unauthorized repair or alterations failures or operating difficulties due to misuse accident improper installation improper maintenance...

Страница 12: ...2 gasket Wrap each pre wrapped unit with 1 8 X 2 gasket Typical Home Installation All KUMA stoves must be installed and operated in accordance with all local state and Federal laws codes and ordinanc...

Отзывы: