Kuller KPG22 Скачать руководство пользователя страница 2

 

Foreword 

 

Thank you for purchasing our gasoline generator and hope that you will enjoy operating your unit, 
one of the finest models in the market. 
 
This Manual provides  information regarding the safe operation and maintenance of this product. It 
is  applicable  for  Models  no.  KPG22-2/KPG22/KPG28/KPG30/KPG42/KPG55/KPG80E  gasoline 
generators. This  manual should be considered a permanent part of the unit and should remain with 
the product if it is resold. 
 
Every effort has been made to ensure the accuracy of the information in this manual. We reserve the 
right to change this product and specifications at any time without prior notice. 

 

Important Message 

 

This  manual  contains  special  messages  to  bring  attention  to  potential  safety  concerns,  generator 
damage  as  well  as  helpful  operating  and  servicing  information.    Please  read  all  the  information 
carefully to avoid injury and machine damage. 
 
Pay special attention to statements with the following symbols and words. 
 

WARNING

  indicates  a  hazard,  if  instructions  are  not  strictly  followed,  can  result  in  human 

injury or death. 

 

CAUTION 

indicates  a  hazard,  if  instructions  are  not  strictly  followed,  could  result  in  human 

injury and/or property damage. 

 

NOTE

            uses to give helpful information. 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание KPG22

Страница 1: ...GASOLINE GENERATOR SET USER S MANUAL...

Страница 2: ...rmation in this manual We reserve the right to change this product and specifications at any time without prior notice Important Message This manual contains special messages to bring attention to pot...

Страница 3: ...5 Use of the Generator Set 10 5 1 Grounding 10 5 2 Wattage of Electrical Devices 10 5 3 Connecting Sequence 10 5 4 Connecting Method 11 5 5 Instructions on AC Usage 11 5 6 Instruction on DC Usage 12...

Страница 4: ...ed or partially enclosed places without good ventilation CAN KILL YOU IN MINUTES Generator exhaust contains Carbon Monoxide a colorless odorless but deadly gas Figure 1 Figure 2 Don t operate the unit...

Страница 5: ...e and or Explosion Gasoline spillage and its vapors are highly flammable and explosive under certain conditions Be aware to fill fuel after stopping the engine Figure 7 WARNING DANGER Fire and or Expl...

Страница 6: ...ge 2 Fuel Tank Cover 3 AC Plug Socket 4 Circuit Breaker 5 Voltmeter 6 Dipstick 7 Ignition Switch 8 Drain Plug 9 Recoil Starter 10 Fuel Switch 11 Air Cleaner 12 Choke Lever 13 Ground Terminal 14 Muffle...

Страница 7: ...ies oil as shown in the chart may be used when the average temperature in your area is within the indicated range NOTE Do the check only when the unit stops operation on a level ground Take out the oi...

Страница 8: ...over and tighten it well Figure 16 CAUTION Don t add a mixture of gasoline and engine oil used for 2 stroke petrol engines Don t use stale fuel Avoid foreign matters getting into the tank such as dust...

Страница 9: ...if the electrolyte level of the battery is between the upper and lower level marked on the battery Figure 20 1 Upper Level 2 Lower Level 3 4 3 Check the specific gravity of electrolyte 3 5 Grounding t...

Страница 10: ...dels Turn the key switch to ON position for E start units Figure 24 Pull up the Starting Handle gently until resistance is felt then pull it up rapidly Put back the handle slowly to avoid damage to th...

Страница 11: ...g Electric Devices Start Rating Incandescent Lamp Heating Devices X 1 X 1 Incandescent Lamp TV Incandescent Lamp 100W 100VA W 100VA W Fluorescent Lamp X 2 X 1 5 Fluorescent Lamp Fluorescent Lamp 40W 8...

Страница 12: ...uaint yourself with the parameters on the Control Panel to ensure correct usage within the rated output of the generator set CAUTION The generator set can work at its rated output only under constant...

Страница 13: ...the devices Figure 31 5 6 Instruction on DC Usage Pay special attention to the connection of positive and negative poles in DC application CAUTION The DC output should not be used as power supply for...

Страница 14: ...al minutes without load to cool down the generator set 6 2 3 Set the ignition switch to OFF position Figure 35 6 2 4 Set the fuel switch to OFF position Figure 36 WARNING Don t touch the heating compo...

Страница 15: ...cessary WARNING Don t carry out any maintenance when the unit is working 7 2 Replacement of Engine Oil Please drain thoroughly the engine oil before the engine completely cooled down to guarantee the...

Страница 16: ...e spark plug and its cap Figure 43 Spark Plug recommended F7TC NOTE Screw in half round more after the spark plug compresses its washer if a new spark plug is used Screw in one fourth round more only...

Страница 17: ...8 2 Operation methods same as Chapter 6 8 3 Stopping the Unit 8 3 1 For emergency Directly turn the ignition switch key to OFF position 8 3 2 For normal condition 8 3 2 1 Turn off the AC breaker and...

Страница 18: ...fresh fuel and adequate amount of gas stabilizer Remove the spark plug and pour into the cylinder a spoon of engine oil pull the recoil start slowly to distribute the oil evenly Re mount the spark plu...

Страница 19: ...5 10 1 4 Remove the spark plug check if there is spark jumping out Figure 56 10 1 5 If the generator set still can not be started after the above steps consult your dealer for help Figure 57 10 2 Fail...

Страница 20: ...Volt Adjustment AVR Automatic Voltage Regulation Ignition CDI Start Type Recoil Start Recoil start electric start Tank Volume 3 5L 15L 25L Minimum Fuel Consumption 395g Kwh Engine Oil Capacity 0 6L 1...

Страница 21: ...20 Kuller Australia Pty Ltd...

Отзывы: