MIG/MAG
- setting the PosT-GAs function
this function ensures the protection of the weld after the welding process.
the function is activated by pressing the FuNctioN button (Fn), the function
is selected by rotating the control n-coder i in sequence, the function parame
-
ter is set by pressing the control n-coder ii.
pulse
double pulse
synergic
manual
N-coder ii
N-coder i
function
MIG/MAG
- setting the INDuCTANCe function
the function affects the arc burning characteristics. the function is only
active in maNual and syNerGic modes. press the n-coder i in turn to
switch to this function. turning the n-coder i clockwise will soften the arc,
reduce metal spatter, and increase arc length. turning the control n-coder i
counterclockwise causes hardening of the arc, increased metal spatter and
decreases the arc length.
inductance setting
synergic
manual
N-coder ii
N-coder i
MIG/MAG
- Adjustment of welding voltage/voltage correction
press the n-coder i in turn to switch to this function.
Manual
- setting the welding voltage
Synergic
- correction of factory voltage value
voltage adjustment / voltage correction
synergic
manual
N-coder ii
N-coder i
MIG/MAG
- setting arc length
the function allows setting the arc length for the pulse and douBle pulse
process. press the n-coder i in turn to switch to this function.
arc length
pulse
double pulse
N-coder ii
N-coder i
MIG/MAG
- setting the 2-sTRoKe function
the function indicates how the welding process is activated. When using this
mode, it is necessary to press the control button during welding, which sends
a signal to activate the welding process. pressing the control button starts the
welding process and activates the sequence of functions. to activate, press
the control button one after the other.
pulse
double pulse
synergic
manual
N-coder ii
control button
2-stroke
MIG/MAG
- setting the 4-sTRoKe function
the function indicates how the welding process is activated. When using this
mode, it is necessary to press and release the control button, which sends a
signal to activate the welding process. the pre-Gas function is then activated,
followed by soFt start and transition to welding power. to complete the
welding process, the control button must be pressed and released again to
terminate the welding process and start the post-Gas function. to activate,
press the control button one after the other.
pulse
double pulse
synergic
manual
N-coder ii
control button
4-stroke