4 - 10
The PG 674 as a programming device
4.6.5. System information
Three pieces of information are displayed with this command:
- type of operating terminal (here: standard type)
- resolution of the initialized encoder (here 360)
- CPU software version (here: V0.1)
Press
Display
Note
Ctrl._
default
360pulses V0.1_
system information
mit beliebiger Taste zur Standardanzeige zurück.
4.6.6. Displaying status and error messages
Display the operating state of the cam control unit:
SHIFT
Run ON
okay message and outputs "ON"
or error message:
Stop OO
encoder error
enc. error and outputs "OFF"
the following is a list of possible error messages:
- encoder error (i.e. no encoder connected, wrong type...)
- battery failure
- short circuit at the output
- check sum (program error)
- undervoltage
- speed too high for the current operating mode
Press any key to return to the standard display.