54
Maintenance
Flexible top link
The flexible top link is kept at a constant tension by two springs. These
springs must have a constant length.
Checking
Distance A between the plate and the pin must be 90 mm.
> Check if distance A is 90 mm
In case distance A is not 90 mm, the distance between the plate and
the pin must be adjusted.
Adjustment
The adjustment of distance A must be adjusted by turning the nut.
> Turn the nut clockwards = distance A increases
or
> Turn the nut counterclockwards = distance A decreases
Spring
Pin
Plate
A
Pin
Plate
A
Nut