80
TROUBLESHOOTING
BATTERY TROUBLESHOOTING
If you have any questions, contact your local KUBOTA Dealer.
MACHINE TROUBLESHOOTING
Trouble
Cause
Countermeasure
Preventive measure
Starter does not function.
A
Battery overused until
lights are dim.
A
Charge battery
sufficiently.
A
Charge the battery properly.
A
Battery has not been
recharged.
A
Poor terminal
connection.
A
Clean the terminal
and tighten securely.
A
Keep the terminal clean and
tight.
Apply grease and treat with
anti-corrosives.
A
Battery life expired.
A
Replace battery.
From beginning starter
does not function, and
lights soon become dim.
A
Insufficient charging.
A
Charge battery
sufficiently.
A
Battery must be serviced
properly before initial use.
A
Insufficient charging.
A
Adjust fan belt.
When viewed from top,
the top of plates look
whitish.
A
Battery was used with
an insufficient amount
of electrolyte.
A
Add distilled water
and charge the
battery.
A
Regularly check the
electrolyte level.
A
Battery was used too
much without
recharging.
A
Charge battery
sufficiently.
A
Charge the battery properly.
Recharging is impossible.
A
Battery life expired.
A
Replace battery.
Terminals are severely
corroded and heat up.
A
Poor terminal
connection.
A
Clean the terminal
and tighten securely.
A
Keep the terminal clean and
tight.
Apply grease and treat with
anti-corrosives.
Battery electrolyte level
drops rapidly.
A
There is a crack or pin
holes in the electrolytic
cells.
A
Replace battery.
A
Charging system
trouble.
A
Contact your local
KUBOTA Dealer.
Trouble
Cause
Countermeasure
Machine operation is not
smooth.
A
Hydrostatic transmission fluid is
insufficient.
A
Fill oil.
A
Filter is clogged.
A
Replace the filter.
Machine dose not move while
engine is running.
A
Parking brake is on.
A
Release the parking brake.
A
Transmission fluid level is
insufficient.
A
Fill oil.
Machine moves when motion
control levers are in "NEUTRAL
LOCK" position.
(Engine is operated.)
A
Hydrostatic lever is not correctly
adjusted.
A
Consult your dealer for hydrostatic lever
linkage adjustment or pressure
adjustment.
A
Control linkage pivots are sticking.
A
Full up and lubricate linkage.
Содержание ZD1011-AU
Страница 15: ...SAFE OPERATION 8 7 DANGER WARNING AND CAUTION LABELS ...
Страница 16: ... 9 SAFE OPERATION ...
Страница 17: ...SAFE OPERATION 10 ...
Страница 18: ... 11 SAFE OPERATION ...
Страница 21: ...SERVICING OF MACHINE 2 1 ROPS serial number ...
Страница 69: ...50 MAINTENANCE PERIODIC SERVICE CHART LABEL 1 Part No K3411 6552 5 ...