GENERAL
ZD1211, ZD1211R, ZD1211L, ZD1211RL, WSM
G-4
4. HANDLING PRECAUTIONS FOR ELECTRICAL
PARTS AND WIRING
To ensure safety and prevent damage to the machine and
surrounding equipment, obey the following precautions in handling
electrical parts and wiring.
IMPORTANT
• Check electrical wiring for damage and loosened
connection every year. To this end, educate the customer
to do his or her own check and at the same time
recommend the dealer to perform periodic check for a fee.
• Do not try to modify or remodel any electrical parts and
wiring.
• When removing the battery cables, disconnect the negative
cable first. When installing the battery cables, connect the
positive cable first.
WSM000001GEG0062US0
[1] WIRING
• Securely tighten wiring terminals.
WSM000001GEG0063US0
• Do not let wiring contact dangerous part.
WSM000001GEG0064US0
• Securely insert grommet.
WSM000001GEG0066US0
(1) Negative Terminal
(2) Positive Terminal
(1) Correct
(Securely Tighten)
(2) Incorrect
(Loosening Leads to damaged
Contact)
(1) Dangerous Part (Sharp Edge)
(2) Wiring (Incorrect)
(3) Wiring (Correct)
(4) Dangerous Part
(1) Grommet
(A) Correct
(B) Incorrect
KiSC issued 06, 2017 A
Содержание WSM ZD1211
Страница 1: ...ZD1211 ZD1211R ZD1211L ZD1211RL WORKSHOP MANUAL KiSC issued 06 2017 A ...
Страница 4: ...I INFORMATION KiSC issued 06 2017 A Find manuals at https best manuals com ...
Страница 11: ...INFORMATION ZD1211 ZD1211R ZD1211L ZD1211RL WSM I 6 9Y1211344INI0003US0 KiSC issued 06 2017 A ...
Страница 15: ...INFORMATION ZD1211 ZD1211R ZD1211L ZD1211RL WSM I 10 4 DIMENSIONS 9Y1211344INI0008US0 KiSC issued 06 2017 A ...
Страница 16: ...G GENERAL KiSC issued 06 2017 A ...
Страница 31: ...This as a preview PDF file from best manuals com Download full PDF manual at best manuals com ...