Bill Validator related

Error 

codes

Occurring Error

80 Jammed bill 
81 Bill dispensing error
82 Cashbox full

83 Stacker error

84 Identifier error
85 Safety switch error

86 Cashbox unlocked

87 Bill extracted

Remove jammed bill.

Collect bill. 

Close the lid.

Close back lid of the identifier.

Close the lid.

Leave it for 30 minutes, or open 
and shut the lid.

Check for jammed bill. 

Remove jammed bill.

Check for jammed bill. 

Empty the cashbox.
Check that stacker lid is closed 
correctly.

Check condition of the identifier. 
Check that cashbox lid is closed 
correctly.
Detected bill extraction , check 
for jammed bill.

Check if the bill could be properly accepted and 
returned.
Error code cleared.

Check point

Action

Recovery verification

Sold-out 

columns

Error 

codes

Occurring Error

90

91

96

500

501

502

503

504

505

506

550

552

555

560

565

559

564

569

574

Check point

Action

Recovery verification

Sold-out 

columns

Cooling unit failure

Heating unit failure 

Door switch error 

Clogged condenser 
warning 

HOT / COLD setting 
error 

 

Compartment 1 fan 
failure 
Compartment 2 fan 
failure 

 

Compartment 3 fan 
failure 
Compartment 4 fan 
failure 
Condenser Fan Failure
Condenser thermistor 
error 

External thermistor 
error 

 

Compartment 1 
evaporator thermistor 
error
Compartment 2 
evaporator thermistor 
error
Compartment 3 
evaporator thermistor 
error
Compartment 1 
thermistor error
Compartment 2 
thermistor error
Compartment 3 
thermistor error
Compartment 4 
thermistor error

Check slave control board 
connector for disconnection.
Check refrigeration unit.
Check slave control board 
connector for disconnection.
Check heating unit.

Check main door switch.

Check condition of the condenser. 

Check HOT/COLD selection 
switch.
Check harness and connectors 
for disconnection.

Check compartment 1 fan motor. 

Check compartment 2 fan motor.

Check compartment 3 fan motor. 

Check compartment 4 fan motor. 

Check condenser fan motor.
Check condenser thermistor 
connector for disconnection. 

 

Check condenser external 
thermistor connector for 
disconnection.
Check compartment 1 
evaporator thermistor connector 
for disconnection.
Check compartment 2 
evaporator thermistor connector 
for disconnection.
Check compartment 3 
evaporator thermistor connector 
for disconnection.
Check compartment 1 thermistor 
connector for disconnection.
Check compartment 2 thermistor 
connector for disconnection.
Check compartment 3 thermistor 
connector for disconnection.
Check compartment 4 thermistor 
connector for disconnection.

If there seems to be no problem, 
replace the slave control board or 
refrigeration unit.
If there seems to be no problem, 
replace the slave control board or 
heating unit. 
If there seems to be no problem, 
replace the main door switch.

Clean the condenser. 

Redo setting correctly.
Reconnect harness.

Reconnect harness.
If there seems to be no problem, 
replace fan motor.
(CAUTION: Always reset the 
machine by switching the power 
ON/OFF after corrective action.)

Reconnect harness.
If there seems to be no problem, 
replace the thermistor.
(CAUTION: Always reset the 
machine by switching the power 
ON/OFF after corrective action.)

Corresponding

Column

Similar error shall not occur within two days after 
correction.

Similar error shall not occur within a day after 
correction.

Error code shall respond to opening and closing of 
the door.
Clear error code by pressing Diagnostics/Clear key on 
the keyboard, or press Condenser Malfunction key. 

Error code cleared. 

Error codes and Corrective Actions

Cooling and heating system related

TPK 

Vending 

Corporation 

Co., 

Ltd.

Содержание KB-GS-20S

Страница 1: ...button Rapid Consecutive Test Vend Keyboard operated Sequential Test Vend View Clear Total Vend Count and Vend Count per Column View Clear Group Vend Count View Lifetime Vend Count Set View Suspend Vending Hours Column Set View Suspend Vending Mode Set View Alternate Sales Set View Space to Sales Set View Product Pricing View Clear Occurring Error Code Mode Key Operations Group Count Setting Free ...

Страница 2: ...s the key after it is done Condenser is normal when the LED is not on Total amount for each counter from G1 to G10 could be viewed by pressing the key View Counter Press Counter key to view counters for each grouping 1 Counter will indicate total amount at first Press Counter key to show count by grouping show count by grouping 2 Next counter will be displayed by pressing the key again 3 Indicated...

Страница 3: ...for each pattern A B and C 0 A B C Hours between 0 24 Hours between 0 24 00 00 23 59 1 1 12 31 Four digits Hours between 0 24 Hours between 0 24 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday none Operation Indicator Function Data 0 Turning off priority 1 Lighting priority 2 Only the timer control 3 Only the sensor control 4 Timer control priority 1 Latest 2 Late 3 Intermed...

Страница 4: ... vending may be suspended for about 7 10 minutes to avoid overheating the solenoid Test session will be ended in 3 vend operations after sold out Return to procedure 2 to continue testing other columns If multiple columns had been selected during procedure 2 proceed on from procedure 3 Press Mode Key to begin testing Press Mode Key to cease testing Press Mode Key again to resume Consecutive Test V...

Страница 5: ...tial Test Column 1 Sequential Test Column 3 01 Count TC 345678 CLR 0 CLR 0 01 Count Column Column 7 123456 01 Count Column Column 8 234567 Press 12 1 2 View Lifetime Vend Count Proce dure Key Indication Operation Press Sales Count Key twelve times Lifetime count of vends from product purchase will be displayed Press END Key to return to normal operation If total count exceeds 6 digits only the low...

Страница 6: ...ostics Clear Key End will be displayed if there is no error Press UP key to view next error code 1 2 3 Set View Space to Sales Proce dure Key Indication Operation Selection button with Sold out lamps turned on indicates that it is not connected to any column End will appear on the display after reached the final column Skip procedure 2 if only viewing the setting Press Set Column Key Vend lamps of...

Страница 7: ...te display 5 Press desired selection button to connect to the column 6 Press the selection button again to cancel connection End will be displayed after setting the last column 8 Press END Key to return to normal operation 31 10 2011 12 34 T 567890 Press UP or DOWN Key to select function number 1 5 Press SET Key Next unassigned column will appear on the display Repeat procedures 5 6 and 7 to compl...

Страница 8: ...e Range 7 C1 C Pattern Time Range 1 C2 C Pattern Time Range 2 C3 C Pattern Time Range 3 C4 C Pattern Time Range 4 C5 C Pattern Time Range 5 C6 C Pattern Time Range 6 C7 C Pattern Time Range 7 End End will appear on the display after reached the final time range Press UP or DOWN Key to return to the beginning or the last Repeat procedures 5 14 to complete set up Repeat procedures 6 and 7 to complet...

Страница 9: ...umber 2 5 6 7 10 Press Set Key Press Set Key Press END Key to return to normal operation 31 10 2011 12 34 T 567890 Press UP or DOWN Key to select function number 4 Press UP or DOWN Key to set start time Press Set Key 8 9 Press UP or DOWN Key to set end time Press Set Key System uses 24 hour clock Selectable hours are from 0 24 Power Saving will be disabled when set to 0000 Proce dure Key Indicatio...

Страница 10: ...start time and end time of light saving hour is set to same time NOTE Set Lighting Setting switch to AUTO Proce dure Key Indication Operation Press END Key to return to normal operation 1 2 4 5 3 6 Press Mode Key Press Set Key 7 8 Press UP or DOWN Key to select mode number 3 Press UP or DOWN Key to select function number 2 Press UP or DOWN Key to select setting Press Set Key Daylight Sensor Sensit...

Страница 11: ...s UP or DOWN Key to select illumination beginning hour Upper 2 digits are the beginning hour Press Set Key Press Set Key to confirm setting Press UP or DOWN Key to select illumination ending hour Lower 2 digits are the ending hour Press Set Key to confirm setting Selectable hours are from 0 24 When beginning and ending hours are set at similar time e g 0024 illumination will be consistently turned...

Страница 12: ...columns All Columns All Columns All Columns ー ー Error codes 34 Selection switch error 38 Vend management error 41 Dispensing motor failure If there seems to be no problem replace the selection button If there seems to be no problem replace the component Check for stuck selection button with sold out Check delivery and vend mechanism Sold out columns Similar error shall not occur within 1 minute af...

Страница 13: ... Check HOT COLD selection switch Check harness and connectors for disconnection Check compartment 1 fan motor Check compartment 2 fan motor Check compartment 3 fan motor Check compartment 4 fan motor Check condenser fan motor Check condenser thermistor connector for disconnection Check condenser external thermistor connector for disconnection Check compartment 1 evaporator thermistor connector for...

Страница 14: ...stor connector for disconnection Check compartment 2 delivery thermistor connector for disconnection Check compartment 3 delivery thermistor connector for disconnection Check compartment 4 delivery thermistor connector for disconnection Reconnect harness If there seems to be no problem replace the thermistor CAUTION Always reset the machine by switching the power ON OFF after corrective action Err...

Страница 15: ... 14 T P K V e n d i n g C o r p o r a t i o n C o L t d ...

Страница 16: ...3022 75436 00 T P K V e n d i n g C o r p o r a t i o n C o L t d ...

Отзывы: