background image

-10-

Mode Key Operations

Proce

-dure

Key

Indication

Operation

Press END Key to return to normal 
operation.

Press UP or DOWN Key to select 
mode number 3.

Press Mode Key.

Press Set Key.

Press UP or DOWN Key to select 
function number 30.

Press Set Key to confirm setting.

Press Set Key.

Press UP or DOWN Key to select 
desired setting.

・Illumination will be enabled under following conditions: 

 

 

 - Selection button illumination pattern is set to "0". 

 

 

 - Selection button illumination hours are set to "0000" or hours out of preset 
   illumination hours. 

 

 

 - Out of service. 

 

 

 - Door opened. 

Selection Button Illumination Pattern 3-30

Proce

-dure

Key

Indication

Operation

Press END Key to return to normal 
operation.

10

Press Mode Key.

Press Set Key.

Selection Button Illumination Hours  3-31

Press UP or DOWN Key to select 
mode number 3.

Press UP or DOWN Key to select 
function number 31.

Press UP or DOWN Key to select 
illumination beginning hour. (Upper 
2 digits are the beginning hour.)

Press Set Key.

Press Set Key to confirm setting.

Press UP or DOWN Key to select 
illumination ending hour. (Lower 2 
digits are the ending hour.)"

Press Set Key to confirm setting.

・Selectable hours are from 0 ~ 24. 

 

 

・When beginning and ending hours are set at similar time (e.g. 0024) illumination 
  will be consistently turned on. 

 

 

・Illumination will not turn on at following conditions: 

 

 

 - Selection button illumination setting is set in "0". 

 

 

 - Selection button illumination hours are set in "0000" or hours out of preset 
   illumination hours. 

 

 

 - Out of service. 

 

 

 - Door opened. 

 

 

“ ” 

10/10/2010 12:34
  T     567890

“ ” 

10/10/2010 12:34
  T     567890

Selection Mode
            1-01

“   ”  

Selection Mode
            1-01

“   ”  

Light Management
            3-01

Light Management
            3-01

Illumination MD
            3-30

Illumination MD
         OFF   0

Illumination MD
     Pattern   1

Illumination MD
     Pattern   1

“   ”  

“   ”  

“   ”  

“   ”  

“   ”  

Light Management
            3-01

Light Management
            3-01

Illumination TM
            3-31

“   ”  

“   ”  

“   ”  

“   ”  

“   ”  

Illumination TM
            0000

“   ”  

Illumination TM
            0800

“   ”  

Illumination TM
            0800

Illumination TM
            0817

Illumination TM
            0817

TPK 

Vending 

Corporation 

Co., 

Ltd.

Содержание KB-GS-20S

Страница 1: ...button Rapid Consecutive Test Vend Keyboard operated Sequential Test Vend View Clear Total Vend Count and Vend Count per Column View Clear Group Vend Count View Lifetime Vend Count Set View Suspend Vending Hours Column Set View Suspend Vending Mode Set View Alternate Sales Set View Space to Sales Set View Product Pricing View Clear Occurring Error Code Mode Key Operations Group Count Setting Free ...

Страница 2: ...s the key after it is done Condenser is normal when the LED is not on Total amount for each counter from G1 to G10 could be viewed by pressing the key View Counter Press Counter key to view counters for each grouping 1 Counter will indicate total amount at first Press Counter key to show count by grouping show count by grouping 2 Next counter will be displayed by pressing the key again 3 Indicated...

Страница 3: ...for each pattern A B and C 0 A B C Hours between 0 24 Hours between 0 24 00 00 23 59 1 1 12 31 Four digits Hours between 0 24 Hours between 0 24 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday none Operation Indicator Function Data 0 Turning off priority 1 Lighting priority 2 Only the timer control 3 Only the sensor control 4 Timer control priority 1 Latest 2 Late 3 Intermed...

Страница 4: ... vending may be suspended for about 7 10 minutes to avoid overheating the solenoid Test session will be ended in 3 vend operations after sold out Return to procedure 2 to continue testing other columns If multiple columns had been selected during procedure 2 proceed on from procedure 3 Press Mode Key to begin testing Press Mode Key to cease testing Press Mode Key again to resume Consecutive Test V...

Страница 5: ...tial Test Column 1 Sequential Test Column 3 01 Count TC 345678 CLR 0 CLR 0 01 Count Column Column 7 123456 01 Count Column Column 8 234567 Press 12 1 2 View Lifetime Vend Count Proce dure Key Indication Operation Press Sales Count Key twelve times Lifetime count of vends from product purchase will be displayed Press END Key to return to normal operation If total count exceeds 6 digits only the low...

Страница 6: ...ostics Clear Key End will be displayed if there is no error Press UP key to view next error code 1 2 3 Set View Space to Sales Proce dure Key Indication Operation Selection button with Sold out lamps turned on indicates that it is not connected to any column End will appear on the display after reached the final column Skip procedure 2 if only viewing the setting Press Set Column Key Vend lamps of...

Страница 7: ...te display 5 Press desired selection button to connect to the column 6 Press the selection button again to cancel connection End will be displayed after setting the last column 8 Press END Key to return to normal operation 31 10 2011 12 34 T 567890 Press UP or DOWN Key to select function number 1 5 Press SET Key Next unassigned column will appear on the display Repeat procedures 5 6 and 7 to compl...

Страница 8: ...e Range 7 C1 C Pattern Time Range 1 C2 C Pattern Time Range 2 C3 C Pattern Time Range 3 C4 C Pattern Time Range 4 C5 C Pattern Time Range 5 C6 C Pattern Time Range 6 C7 C Pattern Time Range 7 End End will appear on the display after reached the final time range Press UP or DOWN Key to return to the beginning or the last Repeat procedures 5 14 to complete set up Repeat procedures 6 and 7 to complet...

Страница 9: ...umber 2 5 6 7 10 Press Set Key Press Set Key Press END Key to return to normal operation 31 10 2011 12 34 T 567890 Press UP or DOWN Key to select function number 4 Press UP or DOWN Key to set start time Press Set Key 8 9 Press UP or DOWN Key to set end time Press Set Key System uses 24 hour clock Selectable hours are from 0 24 Power Saving will be disabled when set to 0000 Proce dure Key Indicatio...

Страница 10: ...start time and end time of light saving hour is set to same time NOTE Set Lighting Setting switch to AUTO Proce dure Key Indication Operation Press END Key to return to normal operation 1 2 4 5 3 6 Press Mode Key Press Set Key 7 8 Press UP or DOWN Key to select mode number 3 Press UP or DOWN Key to select function number 2 Press UP or DOWN Key to select setting Press Set Key Daylight Sensor Sensit...

Страница 11: ...s UP or DOWN Key to select illumination beginning hour Upper 2 digits are the beginning hour Press Set Key Press Set Key to confirm setting Press UP or DOWN Key to select illumination ending hour Lower 2 digits are the ending hour Press Set Key to confirm setting Selectable hours are from 0 24 When beginning and ending hours are set at similar time e g 0024 illumination will be consistently turned...

Страница 12: ...columns All Columns All Columns All Columns ー ー Error codes 34 Selection switch error 38 Vend management error 41 Dispensing motor failure If there seems to be no problem replace the selection button If there seems to be no problem replace the component Check for stuck selection button with sold out Check delivery and vend mechanism Sold out columns Similar error shall not occur within 1 minute af...

Страница 13: ... Check HOT COLD selection switch Check harness and connectors for disconnection Check compartment 1 fan motor Check compartment 2 fan motor Check compartment 3 fan motor Check compartment 4 fan motor Check condenser fan motor Check condenser thermistor connector for disconnection Check condenser external thermistor connector for disconnection Check compartment 1 evaporator thermistor connector for...

Страница 14: ...stor connector for disconnection Check compartment 2 delivery thermistor connector for disconnection Check compartment 3 delivery thermistor connector for disconnection Check compartment 4 delivery thermistor connector for disconnection Reconnect harness If there seems to be no problem replace the thermistor CAUTION Always reset the machine by switching the power ON OFF after corrective action Err...

Страница 15: ... 14 T P K V e n d i n g C o r p o r a t i o n C o L t d ...

Страница 16: ...3022 75436 00 T P K V e n d i n g C o r p o r a t i o n C o L t d ...

Отзывы: