2. Technical Data
2.1 Miscellaneous Data
Display
5 digit red LED
14.2 mm high
Display range
–19999 ... 99999, with leading zeros suppression
Out of Range Indication
Under-range uuuuu / Over-range ooooo
Data storage
EEPROM, 1 Million storage cycles or 10 Years
Test voltages
EN 61010 Part 1 ; overvoltage category 2, level 2
EMC
Interference emissions EN 50081-2 / EN 55011 Class B
Interference resistance EN 61000-6-2
2.2 Electrical Data
2.2.1 Power supply
AC power supply
90 ... 260 V AC/max. 6 VA
external fuse 100 mA/T
DC power supply
10 ... 30 V DC, max. 2 W,
galvanically isolated with inverse polarity protection
external fuse 250 mA/T
Mains Hum Filter
digital filter 50 Hz or 60 Hz, programmable
2.2.2 Inputs
Measurement ranges
Current input (DC)
Ranges
0 ... 20 mA, 4 ... 20 mA
Resolution
2 µA
Voltage drop
max. 2 V bei 20 mA
Max. current
50 mA
Voltage input(DC)
Ranges
0 ... 10 V, 2 ... 10 V, ±10 V
Resolution
1 mV
Input resitance
> 2 MV
Max. voltage
± 30 V
A/D converter
Dual-Slope
Measuring speed
approx. 2 measurements/s
Linearity
< 0,1% ±1 Digit for the whole measuring range at an
ambient temperature of 20°C
Zero calibration
automatic
Temperature drift
100 ppm/K