Kübler Group
4 Installation
English
Operation Manual R60087.0009 - 03
EN | 19
UL - Underwriters Laboratories
UL approval
File no. E224618
Relevant standards
UL 61010-1
Indoor use, outdoor use pos-
sible, not designed for direct
UV radiation.
Maximum air humidity
93 %, 40°C [104°F]
Environment
Dry / Wet
Electrical Characteristics
Supply voltage
5 V DC
5 … 30 V DC
10 … 30 V DC
Supply voltage according to
UL 1310
Class 2
Current consumption (no
load)
depending on the selected
encoder type
Protection class according to
EN 61140
III (PELV)
Maximum output frequency
250 kHz
3.3.2 Approvals
The product meets the following criteria:
• UL approval for the North American economic area.
• Compliance with the European Directives:
– EMC: Directive 2014/30/EU
– RoHS: Directive 2011/65/EU
• Compliance with the British Directives:
– EMC: Regulations S.I. 2016/1091
– RoHS: Regulations S.I. 2012/3032
The declaration of conformity and all certificates relating to
the product can be found on the homepage.
www.kuebler.com/de/docu-finder
4 Installation
4.1 Mechanical Installation
ATTENTION
Damage to the device due to transport or storage
Device failure, malfunction, device lifetime reduction.
• Check the packaging and the device for possible damages.
• In the event of visible damages, do not use the device and
do not put it into operation.
• Do not install the device after falling or being dropped.
• Send damaged encoders back to the manufacturer with a
completed return form (RMA).