15 Input modes: Timing
Function
Diagram
PNP: Count on rising edge
NPN: Count on falling edge
InA.InB
Inp A: Start
Inp B: Stop
Add: Display 0 --> Preset
Sub: Display Preset -> 0
InB.InB
Inp A: no function
Inp B: Start/Stop
Add: Display 0 --> Preset
Sub: Display Preset -> 0
FrRrun
Inp A: no function
Inp B: no function
Control of the timing only
via the GATE input
Add: Display 0 --> Preset
Sub: Display Preset -> 0
Auto
Inp A: no function
Inp B: no function
Control of the timing via
RESET (manual or
electrical)
Add: Display 0 --> Preset
Sub: Display Preset -> 0
Page 24