www.kuebler.com
Page
14
SUB mode output operations:
timed output at Output 1,
becomes active when count <
Preset 1 (Activation only in
negative direction)
ADD mode output operations:
timed signal at Output 1,
becomes passive when count >
Preset 1. (Deactivation only in
positive direction)
SUB mode output operations:
timed output at Output 1,
becomes passive when count <
Preset 1. (Deactivation only in
negative direction).
ADD mode output operations:
timed signal at Output1,
becomes active with positive
direction and when count >
Preset 1 and subsequently active
with negative direction and when
count < Preset 1
SUB mode output operations:
timed signal at Output 1,
becomes active with negative
direction and when count <
Preset 1 and subsequently active
with positive direction and when
count > Preset 1
ADD mode output operations:
timed signal at Output1,
becomes passive with positive
direction and when count >
Preset 1 and subsequently
passive with negative direction
and when count < Preset 1
SUB mode output operations:
timed output at Output 1,
becomes passive with negative
direction and when count <
Preset 1 and subsequently
passive with positive direction
and when count > Preset 1
Duration of timed signal of
Output 1, programmable from
00.01 to 99.99 s.
Timed signal is post-triggered
7.8.6.6 Submenu for Preset 2
Submenu for Preset 2
ADD mode output operations:
permanent signal at Output 2,
becomes active when count >
Preset 2
SUB mode output operations:
permanent signal at Output 2,
becomes active when count <
zero
ADD mode output operations:
permanent signal at Output 2,
becomes passive when count >
Preset 2
SUB mode output operations:
permanent signal at Output 2,
becomes passive when count <
zero
ADD mode output operations:
timed signal at Output 2,
becomes active when count >
Preset 2 (Activation only in
positive direction).
SUB mode output operations:
permanent signal at Output 2,
becomes active when count <
zero (Activation only in negative
direction)
ADD mode output operations:
timed signal at Output 2,
becomes passive when count >
Preset 2 (Deactivation only in
positive direction)
SUB mode output operations:
permanent signal at Output 2,
becomes passive when count <
zero (Deactivation only in
negative direction).
ADD mode output operations:
timed signal at Output 2,
becomes active with positive
direction and when count >
Preset 2 and subsequently with
negative direction and when
count < Preset 2
SUB mode output operations:
timed signal at Output 2,
becomes active with negative
direction and when count < zero
and subsequently with positive
direction and when count > zero
ADD mode output operations:
timed signal at Output 2,
becomes passive with positive
direction and when count >
Preset 2 and subsequently with
negative direction and when
count < Preset 2
SUB mode output operations:
timed signal at Output 2,
becomes passive with negative
direction and when count < zero
and subsequently with positive
direction and when count > zero
Содержание CODIX 924-6
Страница 25: ...deutsch www kuebler com Seite 25 Schalttafelausschnitt...
Страница 26: ......
Страница 27: ...english...
Страница 51: ...www kuebler com Page 25 Panel cut out english...
Страница 52: ......
Страница 53: ...fran ais...
Страница 78: ...www kuebler com Page 26 D coupe d encastrement...
Страница 79: ...italiano...
Страница 104: ...www kuebler com Pagina 26 Apertura d incastro...
Страница 105: ...espa ol...
Страница 130: ...www kuebler com P gina 26 Recorte del cuadro de mando...
Страница 131: ......