Timing can only be controlled via
the Gate input
Inp A and Inp B: no function
The timer is reset by means of a
RESET (to zero when adding, to
preset 2 when subtracting) and
then starts timing again.
Timing is stopped with adding
operations when preset 2 is
reached.
Timing is stopped with
subtracting operations when zero
is reached.
A RESET during the timing
process also causes this to stop.
Inp A and Inp B: no function.
Gate control for Timing
Timing takes place when the
Gate input is not active.
Timing takes place when the
Gate input is active
User input
When the MPI input is activated
the display is “frozen” and
remains “frozen” until the MPI
input is deactivated.
Internally the preset timer
continues counting.
When the MPI input is activated
the current count value for the
preset that has just been
selected will be adopted as the
new preset value.
See also 7.9
When the MPI input is activated
the preset timer will be set to the
value specified in the parameter
SEtPt
. See also 7.10
Lock input
When the Lock input is activated
the programming is inhibited.
When the Lock input is activated
the setting of the preset values is
inhibited.
When the Lock input is activated
the setting of the preset values
and the programming are both
inhibited.
7.8.6.2 Submenu for the output operations
Submenu for determining the
operation of the outputs
Count mode ADD
Outputs active when count status
> preset value
Reset to zero
Count mode SUBTRACT
Output 1, 3, 4, 5 and 6 active
when count status < preset value
1, 3, 4, 5 and 6
Output 2 active when
count status < 0
Reset to preset 2
Count mode ADDING with
automatic reset
Output 1, 3, 4, 5 and 6 active
when count status > preset value
1, 3, 4, 5 and 6
Output 2 (timed signal) active
when count status = preset value 2
Automatic reset to zero when
count status = preset value 2
Reset to zero
Count mode SUBTRACTING
with automatic
reset
Output 1, 3, 4, 5 and 6 active
when count status < preset value
1, 3, 4, 5 and 6
Output 2 (timed signal) active
when count status = 0
Automatic reset to preset 2 when
count status = 0
Reset to preset 2
Count mode ADDING with
automatic reset and Batch
counter
Output 2 (timed output) active
when main counter = preset
value 2
Automatic reset to zero when
main counter = preset value 2
Outputs 3, 5 and 6 active when
main counter > preset value 3, 5
and 6
Batch counter counts the number
of automatic repetitions of preset
2
Output 1 resp. 4 active when
batch counter > preset 1 resp. 4
Manual reset sets both counters
to zero
Electrical reset sets only main
counter to zero
Содержание CODIX 924-6
Страница 25: ...deutsch www kuebler com Seite 25 Schalttafelausschnitt...
Страница 26: ......
Страница 27: ...english...
Страница 51: ...www kuebler com Page 25 Panel cut out english...
Страница 52: ......
Страница 53: ...fran ais...
Страница 78: ...www kuebler com Page 26 D coupe d encastrement...
Страница 79: ...italiano...
Страница 104: ...www kuebler com Pagina 26 Apertura d incastro...
Страница 105: ...espa ol...
Страница 130: ...www kuebler com P gina 26 Recorte del cuadro de mando...
Страница 131: ......