3 Description
Digital panel meter for displaying measured values, as well as monitoring limit values in industrial
applications.
•
6-digit 14-segment LED display, 14 mm, for displaying measured values and dialogs
•
Running text can be switched on as Help Text
•
Language for the Help Text selectable as English or German
•
Signal input for strain gauges 3.3 mV/V, 3.0 mV/V, 2.0 mV/V, 1.5 mV/V and 1.0 mV/V
•
Sampling rate 10 readings per second
•
Digital filter (1st order) for smoothing display fluctuations with unstable input signals
•
Customised linearisation
•
MIN/MAX memory function
•
Manually-controlled Totaliser function
•
2 Relay outputs (changeover contacts) for limit monitoring
•
Start delay for relay outputs after Power ON
•
Versions for supply voltage 10 ... 30 V DC and 100 … 240 V AC ± 10%
•
Excitation supply 10 V DC / 30 mA for powering 350
Ω
bridges
•
Additional aux. power output 24 V / 30 mA with AC supply
•
Programmable via the front keys
•
Multifunction key and two multifunction inputs, function programmable
4 Display/Operating elements
(1) Display
- 14 segment display, 6-digit, red
- Height of figures 14 mm
(2) Status display, 2 LED annunciators, red
- Switching status of Alarm 1 and Alarm 2
- Indication Function Group or Function
(3) MP-Key and Programming Keys
- Multifunction key (MP-Key)
- Return from Function Group
- Return from Function
- Select previous Function Group
- Select previous Function
- Decrement parameter value
- Select next Function Group
- Select next Function
- Increment parameter value
- Enter a Function Group
- Enter a Function
- Accept the new setting
(4) Space for unit overlay
To enter the Programming Menu
+
> 3 sec
To display Device Type and Software Version
+
+
> 5 sec
To restore factory default settings
+
> 3 sec
english
Page 5
Содержание CODIX 566
Страница 6: ...5 Blockschaltbild 6 Anschlussbelegung Seite 6...
Страница 7: ...7 Bedienkonzept Betriebsmode deutsch Seite 7...
Страница 17: ...Ansteuerung bei steigendem Messsignal Ansteuerung bei fallendem Messsignal deutsch Seite 17...
Страница 28: ...5 Block diagram 6 Connections Page 6...
Страница 29: ...7 Operating concept Operating mode english Page 7...
Страница 31: ...Selecting Function Setting Parameters Accepting Parameters Function Groups Function Parameter english Page 9...
Страница 39: ...Control with incrementing measuring signal Control with decrementing measuring signal english Page 17...
Страница 50: ...5 Synoptique 6 Raccordement Page 6...
Страница 51: ...7 Concept d utilisation mode marche fran ais Page 7...
Страница 61: ...Commande par signal de mesure croissant Commande par signal de mesure d croissant fran ais Page 17...
Страница 72: ...5 Schema a blocchi 6 Collegamento Pagina 6...
Страница 73: ...7 Concetto di utilizzo modalit di funzionamento espa ol italiano Pagina 7...
Страница 94: ...5 Diagrama funcional 6 Conexiones P gina 6...
Страница 95: ...7 Concepto de manejo modo de servicio espa ol P gina 7...
Страница 105: ...Mando con se al de medici n creciente Mando con se al de medici n decreciente espa ol P gina 17...
Страница 111: ......