9.4
Function Multifunction Key
(MP-Key) and Multifunction
inputs (MP-INP)
Reset MIN value memory
x
In the function group MP.KEY, programme the
function RES.MIN to ON. In the operating mode
select the minimum value memory (MINIMU)
and briefly press the MP Key.
x
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to RES.MIN or
R.PEAKS. In the operating mode briefly
activate the multifunction input 1 or
multifunction input 2.
Reset MAX value memory
x
In the function group MP.KEY, programme the
function RES.MAX to ON. In the operating
mode select the maximum value memory
(MAXIMU) and briefly press the MP Key.
x
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to RES.MAX or
R.PEAKS. In the operating mode briefly
activate the multifunction input 1 or
multifunction input 2.
Reset of relay outputs in Latch mode
x
In the function group MP.KEY, programme the
function RES.REL to ON. In the operating mode
briefly press the MP Key.
x
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to RES.REL. In
the operating mode briefly activate the
multifunction input 1 or multifunction input 2.
Display Hold
x
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to DISP.HD. In
the operating mode, select either the current
measured value (ACTUAL) or the totaliser
(TOTAL) and activate multifunction input 1 or
multifunction input 2.
Lock-out Limit Value (Alarm) setting
x
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to LOC.ALR. In
the operating mode, activate multifunction input
1 or multifunction input 2.
Lock-out Programming and Default
setting
x
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to LOC.PRG. In
the operating mode, activate multifunction input
1 or multifunction input 2.
Lock-out Keypad
x
In the function group MP.INP, programme the
function MP.INP1 or MP.INP2 to LOC.KEY. In
the operating mode, activate multifunction input
1 or multifunction input 2.
e
n
g
lis
h
Page 13
www.kuebler.com
Содержание CODIX 564
Страница 5: ...5 Blockschaltbild 6 Anschlussbelegung deutsch Seite 5 www kuebler com...
Страница 6: ...Bedienkonzept Betriebsmode Seite 6 www kuebler com...
Страница 16: ...Ansteuerung bei steigendem Me signal Ansteuerung bei fallendem Me signal Seite 16 www kuebler com...
Страница 27: ...5 Block diagram 6 Connections english Page 5 www kuebler com...
Страница 28: ...7 Operating concept Operating mode Page 6 www kuebler com...
Страница 38: ...Control with incrementing measuring signal Control with decrementing measuring signal Page 16 www kuebler com...
Страница 49: ...5 Synoptique 6 Raccordement fran ais Page 5 www kuebler com...
Страница 93: ...5 Diagrama funcional 6 Conexiones espa ol P gina 5 www kuebler com...