4.1 Input polarity

npn: switching to 0 V

pnp: switching to +24 V

4.2 Activating the 30 Hz filter

max. count frequency
20 kHz

max. count frequency
30 Hz

4.3 Scaling factor (totaliser)

It can be set from 00.0001
up to 99.9999. The
decimal point is set to 4
decimal places.
„0“ won’t be accepted!

4.7 Decimal point (tachometer)

The decimal point defines
the way of displaying the
count values. It does not
affect counting.

0

no decimal place

0.0

 one decimal place

0.00  two decimal places
0.000 three decimal
places

4.4 Decimal point (totaliser)

The decimal point defines
the way of displaying the
count values. It does not
affect counting.

0

no decimal place

0.0

 one decimal place

0.00  two decimal places
0.000 three decimal
places

4.5 Reset mode (totaliser)

manual reset (red key)
and electrical reset

no reset
(red key and reset input
locked)

electrical reset only

manual reset only

4.6 Scaling factor (tachometer)

It can be set from 00.0001
up to 99.9999. The
decimal point is set to 4
decimal places.
„0“ won’t be accepted!

4.8 Display mode (tachometer)

Calculating and displaying
the value to 1/sec

Calculating and displaying
the value to 1/min

Содержание CODIX 525

Страница 1: ...gedrückt so wird die aktuelle Funktion gewechselt und zur Bestätigung tacho oder total angezeigt 3 2 Einstellung der Geräteparameter a Beide Tasten auf der Vorderseite gedrückt halten und Spannungsversorgung einschalten b Auf dem Display erscheint c Sobald die Tasten losgelassen werden er scheint im sekündlichen Wechsel der Menütitel und die aktuelle Menüpunkteinstellung Nach Betätigen einer Taste...

Страница 2: ...t Darstellung des Zähler standes fest Er hat keinen Einfluß auf die Zählung 0 keine Dezimalstelle 0 0 eine Dezimalstelle 0 00 zwei Dezimalstellen 0 000 drei Dezimalstellen 4 3 Faktoreinstellung Summierer Faktor von 00 0001 bis 99 9999 einstellbar Dezimalpunkt fest auf 4 Nachkommastellen einge stellt Eine Einstellung von 0 wird nicht akzeptiert 4 4 Dezimalpunkteinstellung Summierer Der Dezimalpunkt...

Страница 3: ...ch Polarität der Eingangssignale für alle Eingänge gemeinsam programmierbar npn oder pnp Eingangswiderstand ca 10 kW Zählfrequenz 20 kHz auf 30 Hz bedämpfbar Mindestimpulsdauer des Rücksetzeingangs 5 ms Schaltpegel der Eingänge log 0 0 VDC 0 2xUB log 1 0 6 x UB 30 VDC Impulsform beliebig Schmitt Trigger Eingänge Datensicherung EEPROM 1x106 Speicherzyklen oder 10 Jahre Genauigkeit 0 1 Störfestigkei...

Страница 4: ...ther the current value of the totaliser or the frequencymeter is displayed Pressing the right key once the current function total or tacho is displayed for 2 seconds If within this period the right key is pressed again the current function is changed The display shows the new function tacho or total 3 2 Setting the operating parameters a Hold down both keys on front panel and switch on the supply ...

Страница 5: ... 00 two decimal places 0 000 three decimal places 4 4 Decimal point totaliser The decimal point defines the way of displaying the count values It does not affect counting 0 no decimal place 0 0 one decimal place 0 00 two decimal places 0 000 three decimal places 4 5 Reset mode totaliser manual reset red key and electrical reset no reset red key and reset input locked electrical reset only manual r...

Страница 6: ...C Storage temperature 25 C 70 C Weight appr 50 g Protection IP 65 front Cleaning The front of the unit is only to be cleaned with a soft wet water cloth 7 Delivery includes CODIX 525 Panel mounting clip Bezel for screw mount panel cut out 50x25 mm Bezel for clip mount panel cut out 50x25 mm Sealing 8 Ordering code 6 525 012 300 4 9 Max time to wait until 0 is displayed This parameter indicates how...

Страница 7: ...7 english english ...

Страница 8: ...econdes la fonction active total ou tacho Si dans ces deux secondes le bouton de droite est pressé encore une fois la fonction active est modifiée Cette modification est confirmée par l affichage du message tacho ou total 3 2 Réglage des paramètres de l appareil a Presser les deux boutons poussoirs de la face avant et mettre l appareil sous tension b Sur l affichage apparaît le message c Dès relâc...

Страница 9: ...équencemètre Le point décimal détermine le nombre de décimales affichées 0 pas de décimale 0 0 une décimale 0 00 deux décimales 0 000 trois décimales 4 5 Mode de remise à zéro totalisateur RAZ manuelle à l aide du bouton poussoir rouge et électrique Pas de RAZ possible bouton poussoir rouge et entrée de RAZ inhibés RAZ électrique uniquement RAZ manuelle uniquement 4 4 Réglage du point décimal tota...

Страница 10: ...max 50 mA Affichage 6 chiffres LED à 7 segments hauteur 8 mm Polarité des signaux d entrée programmable en commun pour les entrées npn ou pnp Résistance d entrée env 10 kW Fréquence de comptage 20 kHz atténuable à 30 Hz Durée minimum de l impulsion pour l entrée de commande 5 ms Niveau de commutation des entrées log 0 0 V DC 0 2xUB log 1 0 6xUB 30 V DC Forme de l impulsion quelconque entrées à tri...

Страница 11: ...11 français ...

Страница 12: ...12 Fritz Kübler GmbH Zähl und Sensortechnik P O BOX 3440 D 78023 VS Schwenningen GERMANY Tel 49 77 20 39 03 0 FAX 49 77 20 2 15 64 E Mail sales kuebler gmbh de ...

Отзывы: