R60723.0002
–
Index
6c
EN
‐
page
35
/
62
5
RESULT=PRES
Display
value
is
equal
PRESELECTION
1.
A
range
(Preselection
+/
‐
½
Hysteresis)
can
be
defined
and
monitored
in
conjunction
with
the
hysteresis.
With
HYSTERESIS
1
not
equal
0
the
following
switching
condition
is
applied:
Display
value
>
PRESELECTION
1
+
½
HYSTERESIS
1
OFF,
Display
value
<
PRESELECTION
1
‐
½
HYSTERESIS
1
OFF
6
RESULT=0
Display
value
is
zero
(Standstill
after
STANDSTILL
TIME(s)),
e.g.
standstill
monitoring,
(only
in
mode
SPEED
and
PROCESS
TIME).
7
RESULT>=
PRES
‐
>0
Auto
reset
to
zero:
(only
in
mode
TIMER
or
COUNTER)
Display
value
is
greater
or
equal
PRESELECTION
1,
the
display
value
is
set
to
zero.
If
the
BATCH
MODE
is
active,
the
batch
counter
increments
or
decrements
when
the
display
value
is
set
to
zero
and
when
the
corresponding
source
of
supply
MEASUREM.
RESULT,
COUNTER
A
or
COUNTER
B
was
selected.
8
RESULT<=
0
‐
>SET
Auto
set
to
PRESELECTION
1:
(only
in
mode
TIMER
or
COUNTER)
Display
value
is
less
or
equal
zero,
the
display
value
is
set
to
PRESELECTION
1
If
the
BATCH
MODE
is
active,
the
batch
counter
increments
or
decrements
when
the
display
value
is
set
to
PRESELECTION
1
and
when
the
corresponding
source
of
supply
MEASUREM.
RESULT,
COUNTER
A
or
COUNTER
B
was
selected.
9
RES>=PRES
‐
TRAIL
Trailing
PRESELECTION
1:
Display
value
is
greater
or
equal
PRESELECTION
2
–
PRESELECTION
1
ON,
PRESELECTION
1
is
the
trailing
value
from
PRESELECTION
2
10
RESULT>=
PRES
‐
>VALUE
Auto
reset
to
“SET
VALUE”:
(only
in
mode
TIMER
or
COUNTER)
Display
value
is
greater
or
equal
PRESELECTION
1,
the
display
value
is
set
to
the
respective
“SET
VALUE”.
If
the
BATCH
MODE
is
active,
the
batch
counter
increments
or
decrements,
when
the
display
value
is
set
to
the
respective
“SET
VALUE”
and
when
the
corresponding
source
of
supply
MEASUREM.
RESULT,
COUNTER
A
or
COUNTER
B
was
selected.
11
ERROR
SET
Error
message
for
device
errors
HYSTERESIS
1
This
parameter
defines
the
switching
hysteresis
of
the
switch
‐
off
point
for
preselection
1
0
No
switching
hysteresis
…
9999
Switching
hysteresis
of
99999
PULSE
TIME
1
(S)
Duration
of
output
pulse
for
the
switching
condition
of
preselection
1
0.000
No
output
pulse
(static
signal)
…
60.000
Pulse
duration
of
60
seconds