R60723.0002
–
Index
6c
EN
‐
page
29
/
62
5.5
Mode
Counter
In
this
menu
the
operation
as
position
indicator,
impulse
counting,
sum
of
2
inputs,
difference
of
2
inputs
or
up
‐
down
counter
is
defined.
Input
A
and
Input
B
are
used.
This
menu
is
only
displayed
when
the
appropriate
OPERATIONAL
MODE
in
GENERAL
MENU
(5.1)
is
selected.
COUNT
MODE
This
parameter
defines
the
counter
operation.
0
A
SINGLE
Input
A
is
a
counting
input.
Input
B
defines
the
counting
direction:
„LOW“
=
forward
„HIGH“
=
reverse
1
A+B
Sum
counter:
Impulses
at
A
+
Impulses
at
B
2
A
‐
B
Differential
counter:
Impulses
at
A
–
impulses
at
B
3
A/B
90
x1
Quadrature
counter:
Impulses
A,
B
with
edge
counting
x1
4
A/B
90
x2
Quadrature
counter:
Impulses
A,
B
with
edge
counting
x2
5
A/B
90
x4
Quadrature
counter:
Impulses
A,
B
with
edge
counting
x4
FACTOR
Scaling
factor.
With
the
summing
mode
(A+B)
and
the
differential
mode
(A
‐
B)
please
note
that
the
impulse
scaling
factor
will
only
affect
input
A
For
example:
A
setting
of
factor
1.23456
and
100000
input
pulses
will
result
in
a
value
of
123456.
0.00001
Smallest
value
1
Default
value
99.99999
Highest
value
SET
VALUE
In
case
of
a
reset
command
(via
keys,
Control
‐
Inputs
or
PC
‐
user
interface),
the
counter
is
set
to
the
value
entered
here.
‐
99999999
Smallest
value
0
Default
value
+99999999
Highest
value
DECIMAL
POINT
This
value
defines
the
position
of
the
decimal
point.
0
NO
No
decimal
point
1
0000000.0
Decimal
point
at
the
specified
position
2
000000.00
Decimal
point
at
the
specified
position
3
00000.000
Decimal
point
at
the
specified
position
4
0000.0000
Decimal
point
at
the
specified
position
5
000.00000
Decimal
point
at
the
specified
position
6
00.000000
Decimal
point
at
the
specified
position
7
0.0000000
Decimal
point
at
the
specified
position