![KTS-Electronic GPA 3000 DR Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/kts-electronic/gpa-3000-dr/gpa-3000-dr_user-manual_2008272010.webp)
KTS-Electronic GmbH & Co. KG
– GPA 3000 DR
10
3.3 GPA display
After selecting the “GPA” search method you have the option to select a probe.
The sensor value will be shown as a bar graph. The corresponding digits will
appear on the right hand side of the screen.
The calibration value will be shown on the left hand side of the screen.
The search depth will be selectable on the upper part of the display via the
options
„10M“, „15M“, „20M“ and „25M“(M for meter).
The “back”-button leads you back to the search method selecting screen.
The battery status will be shown in the lower right corner of the display.
Fig. 3.5 GPA display
4 Search methods
4.1 GPA search methods
There
must
be a probe connected to the electronic unit to use the GPA search
method.
4.1.1 Search with the universal probe
Switching the electronic unit on via On-/Off-button.
Select your language.
Select “Universal probe” at the probe selection.
The electronic unit should face up while using the probe
Optionally the tablet computer can be connected to the electronic unit via
Bluetooth. (See 5.2)
Place the universal probe so that one of the square ends shows in the direction
you want to search and check both, calibration value and sensor value.
Turn the probe 180° so that the opposite square now face forward and check
the two values again.
Choose the side with values closer to 2.5 as forward direction (as shown in the
following figures).
The distance between the probe and ground should not vary a lot.
Avoid hectic movements and try to walk in straight lines.