KTR DATAFLEX 70 Series Скачать руководство пользователя страница 15

 

DATAFLEX

®

 70/... 

Torque Measuring Shaft 

Operating/Assembly instructions 

KTR-N 
Sheet: 
Edition: 

49017 EN 
15 of 21 

 

Please observe protection 

note ISO 16016. 

Drawn: 

2017-01-02 Shg/Koe 

Replacing: 

KTR-N dated 2017-01-02 

Verified: 

2017-01-02 Shg 

Replaced by: 

 

 

 

 

d) Speed signals N1, N2, N-U, R/L (No. 1, 3, 7, 9) 

The connection housing DF2 has 4 connections 
for speed output: 

-  Two square-wave signals shifted by 90 

degrees (N1, N2) 

-  A scalable voltage output (N-U) with direction 

signal (R/L) 

 

Illustration 15

 

 
 

Outputs N1 and N2 

 
Each of the speed outputs N1 and N2 provide a square-wave signal with a resolution of 2x450 periods per 
revolution (illustration 16). 
 

 

Illustration 16 

 
The speed is calculated as follows: 

N [rpm] = f [Hz] / 7.5

 

 
 
The speed channel signals N1 and N2 have a phase shift of 90 degrees to each other. Depending on the 
rotational direction one of the two signals leads 90° in phase (illustration 17). 
 

 

 

Clockwise 

 

Illustration 17 

 
 
 
 
 
 
 

Assembly 

4.10  Technical description 

Содержание DATAFLEX 70 Series

Страница 1: ...ting Assembly instructions KTR N Sheet Edition 49017 EN 1 of 21 3 Please observe protection note ISO 16016 Drawn 2017 01 02 Shg Koe Replacing KTR N dated 2017 01 02 Verified 2017 01 02 Shg Replaced by...

Страница 2: ...5 2 3 General hazard warnings 5 2 4 Intended use 6 3 Storage transport and packaging 6 3 1 Storage 6 3 2 Transport and packaging 6 4 Assembly 7 4 1 Components of DATAFLEX torque measuring shaft 7 4 2...

Страница 3: ...hysteresis 1 0 1 Influence of temperature 10K 0 05 Nominal temperature range C 0 55 Supply voltage V DC 24 4 Max current consumption mA 100 Torque output Output voltage torque V 10 10 Speed output 2 N...

Страница 4: ...Coupling size of DATAFLEX 70 3000 70 5000 Coupling size of RADEX N 90 115 Dimensions mm Dimension d1 d2 max 90 115 Dimension D1 210 265 Dimension D2 132 163 Dimension L6 330 330 Dimension L7 80 100 D...

Страница 5: ...roduct damages This symbol indicates notes which may contribute to preventing material or machine damage General advice This symbol indicates notes which may contribute to preventing adverse results o...

Страница 6: ...pment we reserve the right for technical modifications The DATAFLEX torque measuring shaft described in here corresponds to the technical status at the time of printing of these operating assembly ins...

Страница 7: ...osition of DATAFLEX is variable The measurement system can be mounted both horizontally and vertically Components of DATAFLEX torque measuring shaft Components of RADEX N coupling Component Quantity C...

Страница 8: ...tion 4 Concentricity and axial runout The displacement figures specified in table 4 provide for sufficient safety to compensate for external influences like for example thermal expansion or foundation...

Страница 9: ...assembly The power transmission is frictionally engaged Fit pair of shaft clamping ring hub is specified with H7 h6 The following process should be observed with the assembly Please clean and degreas...

Страница 10: ...side see illustration 9 The ends of the shafts must not protrude through the hubs Shift the power packs in axial direction until the dimension L8 is achieved If the power packs are already firmly asse...

Страница 11: ...he time being with the fit bolts being assembled displaced from left to right see illustration 11 Tighten the fit bolts to the tightening torques mentioned in table 6 by means of a suitable torque key...

Страница 12: ...eaning is not necessary Calibration The transducer is calibrated when being supplied We recommend an annual inspection of the calibration 1 General description The measuring shafts type DATAFLEX 70 ar...

Страница 13: ...y voltage 24V DC 4V 100 mA 11 GND Supply voltage Torque output 4 M U Output voltage 10V 10V RA 1 k 5 GND Ground torque output 6 M I Without function Speed output pulse signal 7 N1 Speed output channel...

Страница 14: ...ation 13 Assignment of torque output values c Filter voltage output No 15 The torque signal may be filtered by activating a low pass filter so that high frequency parts of the signal are eliminated Ta...

Страница 15: ...gnals shifted by 90 degrees N1 N2 A scalable voltage output N U with direction signal R L Illustration 15 Outputs N1 and N2 Each of the speed outputs N1 and N2 provide a square wave signal with a reso...

Страница 16: ...pull outputs providing a square wave voltage with an amplitude of 24V and a maximum switching current of 30 mA The output terminals must not be charged with an external voltage see illustration 18 Th...

Страница 17: ...voltage output Table 11 Switch position S1 S4 and the corresponding scale of the speed output N U Max speed Scaling S1 S2 S3 S4 Illustration 21 10 1 rpm V 0 0 0 0 20 2 rpm V 0 0 0 1 40 4 rpm V 0 0 1...

Страница 18: ...linking of the LEDs of the connection housing Illustration 22 Automatic zero adjustment illustration 23 If the push button T1 is activated for a period of 2 seconds the output of the torque signal is...

Страница 19: ...Each amendment is confirmed by short blinking of the LED L2 Having performed the adjusting the new values are stored lastingly by pressing both push buttons again for 2 seconds The LED L1 is illumina...

Страница 20: ...ition alignment and screw connection of the torque measuring shaft and the condition of the lamina sets of the RADEX N coupling Having started up the torque measuring shaft the tightening torques of t...

Страница 21: ...dated February 26 2014 for harmonizing the legal provisions of the member states regarding electromagnetic compatibility Standards applied DIN EN 61000 6 2 Interference immunity for industrial enviro...

Отзывы: