Oil/air cooler
Series OPC
Operating/Assembly instructions
KTR-N
Sheet:
Edition:
43211 EN
3 of 20
5
Please observe protection
note ISO 16016.
Drawn:
2019-10-23 Pz/Str
Replacing:
KTR-N dated 2017-01-02
Verified:
2019-11-04 Pz
Replaced by:
Type OPC200 to 400
Illustration 1: OPC200 to 400
Table 1: Dimensions - Type OPC200 to 400
Type of cooler
Voltage
Current
[A]
Speed
[rpm]
l/min.
kW/°C
Dimensions [mm]
A
B
C
D
E
OPC200-4D-0.75kW
2
3
0
/4
0
0
V 5
0
Hz
1.8
1400
5.5
0.12
350
460
572
63
255
OPC200-12D-0.75kW
16.7
0.14
OPC200-16D-0.75kW
21.4
0.15
596
OPC300-4D-0.75kW
5.5
0.20
446
550
615
65
300
OPC300-12D-0.75kW
16.7
0.22
OPC300-16D-0.75kW
21.4
0.24
638
OPC400-4D-0.75kW
5.5
0.24
446
550
645
95
300
OPC400-12D-0.75kW
16.7
0.26
OPC400-16D-0.75kW
21.4
0.28
668
OPC400-32D-0.75kW
42.7
0.34
720
Type of cooler
Dimensions [mm]
Weight
[kg]
F
H
I
J
K
L
M
N
OPC200-4D-0.75kW
115
360
174
530
100
330
426
G ¾“
35
OPC200-12D-0.75kW
OPC200-16D-0.75kW
435
G 1“
OPC300-4D-0.75kW
160
450
200
530
100
330
464
G ¾“
42
OPC300-12D-0.75kW
OPC300-16D-0.75kW
473
G 1“
OPC400-4D-0.75kW
160
450
200
550
75
400
465
G ¾“
46
OPC400-12D-0.75kW
OPC400-16D-0.75kW
474
G 1“
OPC400-32D-0.75kW
SAE
1 ½“
1
Technical data