KTM META SYSTEM DEF-COM T Скачать руководство пользователя страница 8

SPECIFICATIONS

Power supply
Consumption
Consumption in Stop mode
Operating temperature
Sound level of siren (1 m)
Self-supply autonomy
Remote controls
Sensitivity of internal movement sensor

12Vcc (10V-15V)

1,8 mA

0 mA

- 25°C + 85°C

114 dB

5 minutes

72 million billion variable codes (lithium battery)

1,5° per second

CAPACTITY OF CONTROLS

Direction indicator relay
Horn control

5A + 5A

Negative electronic 300mA

TIMING

Initial immunity phase
Duration of alarm cycle
Interval between alarm cycles
Passive arming delay
Stop mode delay
Intermittence of direction indicators

26 seconds
26 seconds

5 seconds

50 seconds

5 days

0,4 sec.off/0,4 sec.on

EN

17

ALARM CYCLES

Contact alarm inputs
Ignition sensing
Cable tampering

10 

cycles

10 

cycles

9 cycles

V81548A Is.Uso Def-Com3 KTM  23-11-2006  16:28  Pagina 17

Содержание META SYSTEM DEF-COM T

Страница 1: ...lashes 2 BEEP Arming without internal lift and tilt sensor On fixed during initial immunity phase flashes 2 1 BEEP 2 1 Arming with open contact Flashing 2 flashes 2 BEEP 1 BOOP Initial immunity phase Reversed flashing Testing during the initial immunity phase Reversed flashing 1 BEEP Central unit armed Flashing Alarm cycles Flashing lampeggianti Sounds Disarming without alarms Switches off 1 flash...

Страница 2: ...he initial immunity phase and then flashes normally DISARMING Press the button A of the remote control briefly the direction indicators flash once the siren emits 1 BEEP sound and the LED switches off if no alarms have been triggered while the alarm system was active If the LED remains on and the siren also emits a BOOP sound this means that the alarm system was triggered To find out how the alarm...

Страница 3: ...ically passive arming if no alarms were triggered in this time If the motorcycle s battery is almost flat To exit STOP MODE turn the ignition key ON the siren will emit a series of BEEP sounds Press the remote control within 5 seconds of the BEEPS to disarm the alarm system If the remote control is not pressed within 5 seconds an alarm cycle will be triggered EMERGENCY BLINKER The Motorcycle s Bli...

Страница 4: ... settings described in the first column are required see table BEEP column 7 briefly press the button A of the remote control twice if the settings described in the second column are required see table BOOP column 8 turn the ignition key OFF and briefly press the button of the remote control to exit programming mode otherwise repeat from step 5 to set another function FUNCTION BEEP YES NO NO NO NO...

Страница 5: ...f a remote control is lost stolen or damaged it is possible to disarm the alarm system with a 5 digit emergency code called the OVERRIDE code The code is found on the label supplied with the remote controls This label must be kept in a safe place and not with the motorcycle The procedure is operational only after the initial immunity phase is over and if the alarm functions are operational alarm c...

Страница 6: ...3 Keep ON at the third activation confirmation Beep 2 Beep 2 Boop 2 Beep 2 Boop 1 3 2 1 2 OVERRIDE EMERGENCY CODE WITHIN 10 SEC WITHIN 10 SEC 1 2 1 1 3 F G H I L 1 2 1 1 3 EMERGENCY CODE NEW OVERRIDE ON F ON G X1 ON I X1 OFF OFF ON L CUSTOMISING OVERRIDE CODE X2 ON X1 X3 3 SEC PAUSE 3 SEC PAUSE 3 SEC PAUSE 3 SEC PAUSE WITHIN 10 SEC WITHIN 10 SEC WITHIN 10 SEC WITHIN 10 SEC WITHIN 10 SEC OFF OFF OF...

Страница 7: ...ss the button A of the remote control to be included the LED flashes to confirm reception 6 press the button A of the same remote control again a BEEP sound the LED switching OFF confirms it has been memorised 7 repeat steps 5 and 6 for all the remote controls to be included Any remote controls that are not used e g if lost will be excluded 8 turn the ignition key OFF a series of BEEP BEEP BOOP BO...

Страница 8: ... 5 per second CAPACTITY OF CONTROLS Direction indicator relay Horn control 5A 5A Negative electronic 300mA TIMING Initial immunity phase Duration of alarm cycle Interval between alarm cycles Passive arming delay Stop mode delay Intermittence of direction indicators 26 seconds 26 seconds 5 seconds 50 seconds 5 days 0 4 sec off 0 4 sec on EN 17 ALARM CYCLES Contact alarm inputs Ignition sensing Cabl...

Отзывы: