background image

PROTECTION BY THE ALARM SYSTEM

The alarm central unit protects the motorcycle against being started and an alarm cycle will be triggered every time:
- the ignition key is turned ON
- an attempt is made to remove or move any part of the motorcycle which is protected by specific switches (for example if the seat or
the storage compartment is opened …
- the motorcycle is moved
- the alarm system’s supply cables are disconnected or cut or if the motorcycle’s battery is disconnected

STOP MODE – LIMITING CURRENT CONSUMPTION 

The alarm system automatically switches off in order to limit the consumption of current in the motorcycle’s battery, automatically
excluding the alarm functions but maintaining the immobilisation of the engine. In this condition current consumption is nil.
STOP MODE is activated 5 days after the system was armed by remote control or automatically (passive arming) if no alarms were
triggered in this time;
- If the motorcycle’s battery is almost flat.
To exit STOP MODE, turn the ignition key ON: the siren will emit a series of BEEP sounds. Press the remote control within 5 seconds of
the BEEPS to disarm the alarm system. If the remote control is not pressed within 5 seconds, an alarm cycle will be triggered.

EMERGENCY BLINKER

The Motorcycle’s Blinker can be armed by remote control.
To arm, press button A on the remote control 2 times when the ignition key is in the ON position.
To disarm, press button A on the remote control 1 time when the ignition key is in the ON position.

NB: When the Blinker has been armed by remote control and the ignition key is in the OFF position, the alarm can be armed: this will
automatically neutralise the internal lift and tilt sensor 

PANIC

It is possible to trigger a 10 second alarm cycle by pressing the B button on the remote control. This alarm cycle can be interrupted by
pressing the same button again.

12

EN

V81548A Is.Uso Def-Com3 KTM  23-11-2006  16:28  Pagina 12

Содержание META SYSTEM DEF-COM T

Страница 1: ...lashes 2 BEEP Arming without internal lift and tilt sensor On fixed during initial immunity phase flashes 2 1 BEEP 2 1 Arming with open contact Flashing 2 flashes 2 BEEP 1 BOOP Initial immunity phase Reversed flashing Testing during the initial immunity phase Reversed flashing 1 BEEP Central unit armed Flashing Alarm cycles Flashing lampeggianti Sounds Disarming without alarms Switches off 1 flash...

Страница 2: ...he initial immunity phase and then flashes normally DISARMING Press the button A of the remote control briefly the direction indicators flash once the siren emits 1 BEEP sound and the LED switches off if no alarms have been triggered while the alarm system was active If the LED remains on and the siren also emits a BOOP sound this means that the alarm system was triggered To find out how the alarm...

Страница 3: ...ically passive arming if no alarms were triggered in this time If the motorcycle s battery is almost flat To exit STOP MODE turn the ignition key ON the siren will emit a series of BEEP sounds Press the remote control within 5 seconds of the BEEPS to disarm the alarm system If the remote control is not pressed within 5 seconds an alarm cycle will be triggered EMERGENCY BLINKER The Motorcycle s Bli...

Страница 4: ... settings described in the first column are required see table BEEP column 7 briefly press the button A of the remote control twice if the settings described in the second column are required see table BOOP column 8 turn the ignition key OFF and briefly press the button of the remote control to exit programming mode otherwise repeat from step 5 to set another function FUNCTION BEEP YES NO NO NO NO...

Страница 5: ...f a remote control is lost stolen or damaged it is possible to disarm the alarm system with a 5 digit emergency code called the OVERRIDE code The code is found on the label supplied with the remote controls This label must be kept in a safe place and not with the motorcycle The procedure is operational only after the initial immunity phase is over and if the alarm functions are operational alarm c...

Страница 6: ...3 Keep ON at the third activation confirmation Beep 2 Beep 2 Boop 2 Beep 2 Boop 1 3 2 1 2 OVERRIDE EMERGENCY CODE WITHIN 10 SEC WITHIN 10 SEC 1 2 1 1 3 F G H I L 1 2 1 1 3 EMERGENCY CODE NEW OVERRIDE ON F ON G X1 ON I X1 OFF OFF ON L CUSTOMISING OVERRIDE CODE X2 ON X1 X3 3 SEC PAUSE 3 SEC PAUSE 3 SEC PAUSE 3 SEC PAUSE WITHIN 10 SEC WITHIN 10 SEC WITHIN 10 SEC WITHIN 10 SEC WITHIN 10 SEC OFF OFF OF...

Страница 7: ...ss the button A of the remote control to be included the LED flashes to confirm reception 6 press the button A of the same remote control again a BEEP sound the LED switching OFF confirms it has been memorised 7 repeat steps 5 and 6 for all the remote controls to be included Any remote controls that are not used e g if lost will be excluded 8 turn the ignition key OFF a series of BEEP BEEP BOOP BO...

Страница 8: ... 5 per second CAPACTITY OF CONTROLS Direction indicator relay Horn control 5A 5A Negative electronic 300mA TIMING Initial immunity phase Duration of alarm cycle Interval between alarm cycles Passive arming delay Stop mode delay Intermittence of direction indicators 26 seconds 26 seconds 5 seconds 50 seconds 5 days 0 4 sec off 0 4 sec on EN 17 ALARM CYCLES Contact alarm inputs Ignition sensing Cabl...

Отзывы: