EQUIPOTENTIAL BONDING CHECK 6
25
310418-51
–
Measure the resistance between the specified points.
High-voltage plug for KTM PowerPack
FV
pin
gnd
–
Measuring point KTM PowerPack housing
< 0.1
Ω
» If the specified value is not reached:
–
Contact KTM customer service.
310419-51
–
Measure the resistance between the specified points.
High-voltage plug for KTM PowerPack
FV
pin
gnd
–
Measuring point KTM PowerPack housing
< 0.1
Ω
» If the specified value is not reached:
–
Contact KTM customer service.
6.2
Performing an equipotential bonding check (KTM PowerPack installed)
Warning
Risk of injury
The measuring points could be live.
–
Use personal protective clothing and comply with the safety measures.
Condition
The KTM PowerPack has been installed.
–
Prepare the special tool for measurement.
AVL DITEST HV Safety 2000 (70029068000)
–
Start software
HV Safety
.
–
Select
"Equipotential bonding check"
.